Fire Alarm System; General Information - Honeywell LYNXR-2 Series Security System User Manual

Hide thumbs Also See for LYNXR-2 Series Security System:
Table of Contents

Advertisement

LYNXR-2 Series is not intended for UL985 Household Fire applications unless a 24-hour backup
UL
UL
UL
UL
battery (P/N LYNXRCHKIT-HC) is installed.
General
Your fire alarm system (if installed) is active 24 hours a day, providing continuous protection. In the
event of an emergency, the installed smoke and heat detectors will automatically activate your security
system, triggering a loud, intermittent sound from the keypad. An intermittent sound will also be
produced by optional exterior sounders, and interlaced with the voice descriptor, sounding every 15
seconds. A "FIRE" message will appear at your keypad and remain on until you silence and clear the
alarm display.
In Case of Fire
1.
Should you become aware of a fire emergency before your detectors sense the problem, go to your
nearest keypad and press the single panic key (or panic key pair) assigned as FIRE emergency (if
programmed by the installer) and hold down for at least 2 seconds. The alarm will sound.
2.
Evacuate all occupants from the premises.
3.
If flames and/or smoke are present, leave the premises and notify your local Fire Department
immediately.
4.
If no flames or smoke are apparent, investigate the cause of the alarm. The zone number of the
zone(s) in an alarm condition will appear at the keypad.
Silencing a Fire Alarm
1.
Silence the alarm by entering:
NOTE: Silencing a fire alarm on the LYNXR-2SIA Control simply requires you to enter your user code.
Pressing the OFF key is not necessary. To clear the alarm however, you must enter your user code
again and then depress the OFF key.
To clear the alarm display, enter:
2.
If the keypad indicates a trouble condition after the second OFF sequence, check that smoke
detectors are not responding to smoke- or heat-producing objects in their vicinity. Should this be
the case, eliminate the source of heat or smoke.
3.
If this does not remedy the problem, there may still be smoke in the detector. Clear it by fanning
the detector for about 30 seconds.
4.
When the problem has been corrected, clear the display by entering:

FIRE ALARM SYSTEM

FIRE ALARM SYSTEM
FIRE ALARM SYSTEM
FIRE ALARM SYSTEM
+ OFF key.
Your user code
+ OFF key again.
Your user code
– 41 –
(If Installed)

General Information

+ OFF key.
Your user code