TG509, TG510, TG511, TG512 VERSAGUARD™ UNIVERSAL THERMOSTAT GUARDS
Junction Box Mounting (Fig. 12)
Place the thermostat subbase (or wallplate) on the
wallplate template and mark the mounting holes.
Locate the mounting holes on the guard wallplate using
the template as a guide.
Drill the required 5/32 in. mounting holes in the guard
wallplate.
Secure the guard wallplate to the ring base using the
screws provided.
Place the guard wallplate (with smooth side facing the
ring base) on the back of the ring base.
Insert the securing screws through the holes on the
front of the ring base and into the posts on the
wallplate. See Fig. 12.
Tighten the screws securely.
NOTES: When using a front-wired subbase
(wallplate), run the system wires from the
junction box through the wiring hole in the
guard wallplate and subbase (wallplate)
cable opening.
HORIZONTAL
OUTLET BOX
GUARD
WALLPLATE
WALLPLATE
POSTS
Fig. 12. Mount guard wallplate with ring base and thermostat on junction box (front-wired thermostat subbase shown).
68-0104—4
RING BASE
SECURING SCREWS (4)
When using a back-wired subbase
(wallplate), run the system wires from the
junction box through the wiring hole in the
guard wallplate only.
Wire the back-wired subbase. Refer to the instructions
provided with the thermostat.
Mount the thermostat subbase (wallplate) and the ring
base with the guard wallplate to the junction box using
the 1-1/4 in. sheet metal screws provided.
Wire the front-wired subbase (wallplate). Refer to the
instructions provided with the thermostat.
Mount the thermostat on the subbase (wallplate).
Place the thermostat cover on the thermostat.
Mount the guard cover by placing the hinged edge of
the guard cover on the ring base and swinging it down
(horizontal mounting) or to the side (vertical mounting)
until the guard cover is in place against the ring base.
See Fig. 7.
Lock the thermostat guard by turning the key (provided)
counterclockwise. See Fig. 8. The key can only be
removed in the locked position.
Remove the paper backing and clear protective cover
from the included monogram and place the monogram
in the recessed area on the guard cover. See Fig. 9.
THERMOSTAT
10
SUBBASE
MOUNTING
SCREWS (2)
O L
C O
8 0
7 0
6 0
5 0
8 0
7 0
6 0
5 0
A T
H E
8 0
7 0
6 0
5 0
M1638A