Cutter Grid; Dual Transformer - KitchenAid Kitchen Aid KAR-19 Technical Education

2007 design 15" & 18" automatic ice makers
Table of Contents

Advertisement

Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.

CUTTER GRID

Refer to page 4-2 for the procedure for access-
ing the cutter grid.
1.
Unplug ice maker or disconnect power.
2.
Set the ohmmeter to the appropriate
scale.
3.
Touch the ohmmeter test leads to the pins
of the cutter grid 2-wire connector. The
meter should indicate 4 to 5 ohms
WARNING
WARNING
Electrical Shock Hazard

DUAL TRANSFORMER

Refer to page 4-5 for the procedure for access-
ing the dual transformer.
1.
Unplug ice maker or disconnect power.
2.
Set the ohmmeter to the appropriate
scale.
3.
Touch the ohmmeter test leads to the
primary black and white leads of the dual
transformer. The meter should indicate
between 3.5 and 4.5 ohms.
4.
Touch the ohmmeter test leads to the sec-
ondary yellow and yellow leads of the dual
transformer. The meter should indicate
between 0.11 and 0.14 ohms.
5.
Touch the ohmmeter test leads to the
secondary red and red leads of the dual
transformer. The meter should indicate
between 0.14 and 0.18 ohms.
5-2

Hide quick links: