Safety Regulations; Electromagnetic Field Specifications - Dell PowerVault 110T SDLT320 User Manual

User manual
Hide thumbs Also See for PowerVault 110T SDLT320:
Table of Contents

Advertisement

Back to Contents Page
Regulatory Compliance: Dell™ PowerVault™ 110T SDLT 320 Tape Drive User's Guide
• Safety Regulations • Electromagnetic Field Specifications • Acoustic

Safety Regulations

This section lists the safety regulations that the PowerVault 110T tape system meets or exceeds, such as UL, CSA, EN/IEC, and "GS" Mark.
Safety Certifications
The SDLT tape system meets or exceeds requirements for safety in the United States (UL 1950), Canada (CSA950 C22.2 No. 950) and Europe (EN60950/IEC 950), and is
certified to bear the GS mark.
Safety Requirements
Safety requirements include:
UL1950: Information Technology Including Electrical Business Equipment
CSA950 C22.2 No. 950: Information Technology Including Electrical Business Equipment
EN60950/IEC 950: Information Technology Including Electrical Business Equipment

Electromagnetic Field Specifications

Electromagnetic Emissions
Once the internal tape drive is mounted into an enclosure and grounded, the internal drive complies with FCC Class A; the external tape drive complies with the FCC Class B
limits.
Conducted Emissions
Limits for Class B equipment are in the frequency range from 0.15 to 30 MHz.
Table 1. Conducted Emissions
Frequency Range
 
0.15 to 0.50 MHz
0.50 to 5 MHz
5 to 30 MHz
* The limit decreases linearly with the logarithm of the frequency.
Radiated Emissions
Limits of radiated interference field strength, in the frequency range from 30 MHz to 1000 MHz at a test distance of 10 meters, are listed in Table 2.
Table 2. Radiated Emissions
Frequency Range
 
30 to 230 MHz
230 to 1000 MHz
Above 1000 MHz
Susceptibility and ESD Limits
Table 3 and Table 4 list radiated, magnetic radiated, and conducted susceptibility and ESD failure level limits for the tape drive.
Table 3. Radiated, Magnetic Radiated, and Conducted Susceptibility
Type
Radiated Immunity - High Frequency, Electric Fields
Magnetic Radiated - Low Frequency, Magnetic Fields
EFT- Fast Transient (Bursts) for Power and Data Cables
PLT- High Energy Transient Voltage for Power Cables
Low-Level Conducted ‡ Interference for AC and DC Cables
Quasi-peak
66 to 56*
56
60
Quasi-peak limits dB (µV/m)
Class A
40
46
54
Specifications
3 V/m (rms), 80% modulated, 1 KHz, 26 to 1000 MHz
3 A/m @ 230V/50 Hz
2 kV
1.2 kV (Differential) 2.5 kV (Common mode)
3 V/m (rms), 80% modulated, 1 kHz,
0.15 - 80 MHz
Limits dB
Average
56 to 46
46
50
Class B
30
37
Not applicable
Comments
No errors*
No screen distortion
No errors*
No screen distortion
No errors*
No errors*
No errors*
No screen distortion