Forwall or roofventing methods:
Choose between roof venting or wall venting.
If the wall exhaust method is chosen, be sure that there is
proper clearance within the wall for the exhaust vent.
Vent materials neededfor installationare not included.
Wall and roofcaps must have back-draftdamper.
We recommend:
v' using rigid metal vent.
v' that length of vent and number of elbows should be
kept to a minimum to provide efficient performance.
v' that size of vent should be uniform.
v' using duct tape to seal all joints in the vent system.
v' using caulking compound to seal exterior wall or roof
opening around cap.
v' two elbows should not be installed together.
We do NOT recommend:
v' flexible metal vent.
NOTE: If flexible metal vent must be used, calculate each
foot of flexible metal vent as two feet of rigid metal vent.
Flexible metal elbows count twice as much as standard
elbows.
Roofventing
Salida de alre per el cielo raso
roof cap
¢aperuzade cielo raso
3-1/4"x 10" through*the-roof
a trav_sdelcielorasoperun orificio
de3-1/4"x 10
Wall venting
Salida de alre per la pared
wall cap
caperuz_ depared
3-1/4" x 10" through-the*wall
a trav6s de la pared par un
orificio de 3-1/4" x 10
Roundvent transition
Transici6nde conductode salida de aire redondo
roof cap _
_,.,-,.._
caperuza de _
/
k
cielo raso
6" min. diameter roundvent _
[
[
wall sap
conductode salida de aire
] ."-_t_.
......
._,._,..M_-,_
redondo de6"dedi_metro
I"
I _ _---,
,_
._-_-'.=_._
coda
3-1/4" x 10" to 6" round vent
transition
transicibn deconducto d esalida
3" minimum height (required
for damper to fully open)
Altura minima de 3"
(necesaria para qua la
compaerta se abra
nompletamente)
deaireredondo de3-1/4"x 16"
a6"
vienede la p_,gina 7
Para m_todos de salida de aire a trav6s de la pared o el
cielo raso:
Decida entre instalar la salida de aire a travds del cielo raso o
de una pared.
Si se decide par el mdtodo de salida de aire a travds de la
pared,aseg_rese de que haya el espacio adecuadodentro de
la pared para el conducto de salida de aire.
No se incluyenlos materiales del conductode salida de aire
que se necesitanpara la instaiaci6n.
Las caperuzaspara cielo raso y pared deben tener
compuerta de contratiro.
Recomendamos:
v' usar un conducto de salida de aire met_lico y rigido.
v' que la Iongitud del conducto de salida de aire y el n_mero
de codas se mantengan a un minima pare Iograr un
rendimiento eficiente.
v' que las dimensiones del conducto sean uniformes.
v' usar cinta pare conducto pare sellar todas las uniones en el
sistema de salida de aire.
v' usar masilla pare calafatear pare sellar la pared exterior ola
abertura en el cielo raso alrededor de la caperuza.
v' no se deben instalar dos codas juntos.
No recomendamos:
v' conducto de salida de aire met_lico flexible
NOTA:si debe usarse un conducto metdlico flexible, calcule
cada pie de conducto metdlico flexible coma si fueran dos pies
de conducto metdlico rigido. Los codas de metal flexible hacen
par dos codas estdndar.
8
Recommendedvent length:
Use 3-1/4° X 10" rectangular or 6" round vent.
The total length of the vent system including straight vent,
elbow, transitions, wall or roof caps must not exceed the
equivalent of 140 feet of 3-1/4" X 10" rectangular or 6"
diameter round vent.
For best performance, use no more than three 90 degree
elbows.
To calculate the length of system you need,add the
equivalent feet for each vent piece used in the system. See
the following examples:
3-1/4" x 10" vent system:
1 - 3-1/4" x 10"
90° elbow
= 25 ft.
1 - wall cap
= 40 ft.
8 feet straight
8 ft.
Length of
3-1/4" x 10" system = 73 ft.
6" vent system:
1 - transition
= 5 ft.
2 - 90° elbows
20 ft.
1 - wall cap
= 40 ft.
8 feet straight
8 ft.
Length of 6" system = 73 ft.
If the existing vent is round, a rectangular-to-round adapter
must be used and a rectangular 3" extension vent between
the damper assembly and adapter must be installed to
prevent damper from sticking.
Recommended standardfittings
Accesorios est_ndarrecomendados
3-1/4" x lO"to 6"= 5ft.
De3-1/4"x 1_' a6"=
5 pies
3-1/4' x 10"roofcap = 24 ft.
Capemza decielorasode
3-1/4"x 10' = 24 pies
3-1/4"x 10"
90_dbow =25 ft.
Codede90° y 3-1/4"x
1_' = 25 pies
90° elbow=lOft.
CododegO_=
10 pies
3-1/4"x 10"wallca
=40ft.
Coperuza d epared
de3-1/4"x 10"=
40pies
45° elbow= 5 ft.
Codade45° =
5 pies
3-1/4"x 10' flat
eibow= 10ft.
Codapianode3-1/4"
x 10"= 10 pies
3-1/4" x 10" vent system
Sistemade salida de aire de 3-1/4" x 10"
3-1/4" x 16"
90 ° elbow
Codade90° y
6 It.
3-1/4"x1_
_6pies_
n
wallsap
T" ]
I H_caperuza
de
' I}> parud
U
2_t. (2 pies)
6"vent system
Sistemade salida de aire de 6"
90° elbows
codo de 90°
2
transition
transici6n
2 ft. (2 pies)
Longitudrecomendadadel conductode salida de aire:
Use un conducto de salida de aire rectangular de 3-1/4_x 10"
o redondo de 6".
La Iongitud total del sistema de salida de aire, incluyendo el
conducto de salida de aire recto, el coda, las transiciones, las
caperuzas de pared o cielo raso no deben exceder el
equivalente a 140 pies de conducto rectangular de salida de
aire de 3-1/4" x 10" o conducto redondo de 6" de didmetro.
Para mejores resultados, no use m_s de tres codas de 90°.
Para calcular la Iongitud del sistema que necesita, agregue la
equivalencia en pie para cada pedazode conducto usado en el
sistema. Vea los siguientes ejemplos:
Sistema de salida de aire de 3-1/4" x 10":
1 - Coda de 90°
y 3-1/4" x 10"
= 25 pies
1 - Caperuzade pared
= 40 pies
8 pies recto
= 8 pies
Longitud de un
sistema de 3-1/4" x 10" = 73 pies
Sistema de salida de aire de 6"
1 -transici6n
= 5 pies
2 - codas de 90°
20 pies
1 - caperuza de pared
= 40 pies
8 pies recto
8 pies
Longitud de un
sistema de 6"
= 73 pies
Si el actual conducto de salida de aire es redondo, debe usarse
un adaptador de rectangular a redondo y un conducto de
extension rectangular de 3" entre el conjunto de la compuerta
y se debe instalar el adaptador pare evitar que la compuerta se
atasque.
9