Setting The Timers Of The Radius Server - 3Com 5500-SI Configuration Manual

5500 series
Hide thumbs Also See for 5500-SI:
Table of Contents

Advertisement

Setting the Timers of the
RADIUS Server
Setting the Response Timeout Timer of the RADIUS Server
After RADIUS (authentication/authorization or accounting) request packet has been
transmitted for a period of time, if NAS has not received the response from the
RADIUS server, it has to retransmit the request to guarantee RADIUS service for the
user.
You can use the following command to set response timeout timer of RADIUS server.
Perform the following configurations in RADIUS Scheme View.
Table 466 Setting the Response Timeout Timer of the RADIUS Server
Operation
Set response timeout timer of RADIUS server
Restore the response timeout timer of RADIUS server to default value
By default, timeout timer of RADIUS server is 3 seconds.
Setting a Real-time Accounting Interval
To implement real-time accounting, it is necessary to set a real-time accounting
interval. After the attribute is set, NAS will transmit the accounting information of
online users to the RADIUS server regularly.
You can use the following command to set a real-time accounting interval.
Perform the following configurations in RADIUS Scheme View.
Table 467 Setting a Real-time Accounting Interval
Operation
Set a real-time accounting interval
Restore the default value of the interval
specifies the real-time accounting interval in minutes. The value should be a
minute
multiple of 3.
The value of
is related to the performance of NAS and RADIUS server. The
minute
smaller the value, the higher the performances of NAS and RADIUS that are required.
When there are a large amount of users (more than 1000, inclusive), 3Com suggests
a larger value. Table 468 recommends the ratio of
users.
Table 468 Recommended Ratio of Minute to Number of Users
Number of users
Real-time accounting interval (minute)
1 to 99
3
100 to 499
6
500 to 999
12
1000
15
By default,
is set to 12 minutes.
minute
User Re-authentication at Reboot 429
Command
timer second
undo timer
Command
timer realtime-accounting minute
undo timer realtime-accounting
value to the number of
minute

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

5500-ei5500g-ei

Table of Contents