ATTENTION
Disregard of this precaution could cause the incorrect operation of the touch control system of the
cooktop and effect the product warranty provisions.
WARNING:
All aspects of the installation must conform with the requirement of the Standards North
America (within North America) wiring rules, as well as your local electrical and building
codes and regulations, and any other applicable requirements and conditions of your
local power supply authority. Your appliance must be properly installed and grounded by
a qualified and licensed technician.
240 Volt 60Hz 30AMP single/40AMP double service
Incorrect installation of the appliance, resulting from the kitchen maker not following the detailed
installation specifications, can affect the appliance performance
CONNECTION TO THE GAS SUPPLY: CURRENT INSTALLATION STANDARDS
The cooker should be connected according to local regulations,
using either a rigid or flexible connections.
a) For building in: Use a continuous flexible stainless steel pipe, as
per current installation standards, which can be extended to a
maximum of 2000 mm.; the ends of the pipe must be fitted with
an ISO 228/1coupling and gasket or an ISO 7/1 threaded
coupling with mechanical gasket.
b) For free standing: A non-metallic flexible pipe can be used
as long as it complies with current standards and the
following installation instructions are observed: the pipe
must be longer than 400 mm and shorter than 1500 mm; it
must not exceed 50°C in any point; it is not pulled or
twisted; it cannot be choked and the entire edges, sharp
corners or other similar hazards.
Before connecting the non-metallic flexible pipe, the brass adapter and gasket supplied with
the cooker and/or available form the reseller must be fitted to the pipe/gas train on
the back of the cooker. The regulator provided should be positioned between the brass
adapter and the non metallic flexible pipe.
c) A certified gas plumber must complete the installation and meet with local regulation
requirements for gas connections. Where the unit has an armour cable a certified electrician
must complete the electrical connection. The white, or neutral wi re will not be used and must
be capped using a marrette.