4. MAINTENANCE

4.1.3 Optional Cutter Module

WARNING!
As the cutter blade is sharp,
care should be taken not to
injure yourself when cleaning.
1. Open the Front Cover.
2. Loosen the Set Screw of the Cutter Unit to open it.
3. Remove jammed media, if any.
Cutter Unit
Cutter Unit
4. Clean the inside of the Cutter Blade with a cotton swab moistened
with absolute ethyl alcohol. The cutter blade moves up and down
when the Cutter Motor Shaft is rotated manually.
Inside of the Cutter Blade
5. In the same way, clean the outside of the Cutter Blade.
E4- 3
ENGLISH VERSION EO1-33047
Cutter Motor Shaft
Outside of the Cutter
Blade
4.1 Cleaning
Set Screw