Step 3-Set Jumpers; Table 8-1. Perc 3/Sc Jumpers; Table 8-2. J1 Termination Enable Settings - Dell PowerEdge Expandable RAID Controller 3 User Manual

Expandable raid controller
Table of Contents

Advertisement

Step 3—Set Jumpers
Make sure the jumper settings on the PERC 3/SC card are correct. The
jumpers and connectors are shown in Table 8-1.
Ta b l e 8 - 1 . P E R C 3 / S C J u m p e r s
Connector
Description
J1
SCSI bus termination enable control
J2
CPLD programming
J3
Non-volatile random access memory
(NVRAM) clear
J4
Serial erasable programmable read-
only memory (EPROM)
J5
Serial port
J6
Write pending
J7
BIOS enable
J8
User activity light-emitting diode
(LED)
J9
I2C connector
J10
SCSI bus termination power
J11
Internal straddle-mount connector
J13
External SCSI connector
J15
RUBI slot interrupt steering
J16
RUBI slot interrupt steering
J17
RUBI slot interrupt steering
J1 Termination Enable
J1 is a three-pin header that specifies hardware or software control of SCSI
termination. The default is OPEN. The settings are shown in Table 8-2.
Ta b l e 8 - 2 . J 1 Te r m i n a t i o n E n a b l e S e t t i n g s
Type of SCSI Termination
Software control of SCSI termination using drive
detection.
Type
3-pin header
10-pin header
2-pin header
2-pin header
3-pin header
2-pin header
2-pin header
4-pin connector
4-pin header
2-pin header
68-pin connector
68-pin connector
3-pin header
3-pin header
3-pin header
J10 Setting
Short pins 1-2
PE RC 3/ SC Har d war e In s ta l lati on