Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
BLOWER SPEED RESISTOR
Blower Speed
Resistor Wires
Screw
Refer to page 4-33 for the procedure for ac-
cessing the blower speed resistor.
1.
Unplug oven or disconnect power.
2.
Set the ohmmeter to the R x 1 scale.
3.
Touch the ohmmeter test leads across the
wire connector terminals. The meter should
indicate approximately 170 Ω.
WARNING
Electrical Shock Hazard
OVEN SHUTDOWN THERMAL
CUTOFF (TCO)
Refer to page 4-34 for the procedure for ac-
cessing the oven shutdown thermal cutoff.
1.
Unplug oven or disconnect power.
2.
Set the ohmmeter to the R x 1 scale.
3.
Touch the ohmmeter test leads across the
wire connector terminals. The meter should
indicate a closed circuit (0 Ω).
5-11