Use this table to define the result codes.
Code
Test
7
A-trigs connectivity
11
Stylus excitation
Sensor Antenna
14
disconnects
15
Sensor Antenna shorts Digitizer grid shortcut
18
Channel imbalance
19
Capacitor calibration
Internal Firmware
47
Error
48
Critical Malfunction
49
Host Timeout Error
Capacitor Calibration
50
Required
 
Digitizer Self Test Result Codes
Error Details
Digitizer analog
Digitizer is unable to initialize or read samples from analog processor. No pen or touch position is
processor fail
reported.
Signals received during the stylus excitation test are below certain limit. Pen may be not
No pen excitation
functional or detected in tip only.
There are disconnected lines. Pen or touch may be malfunctioning in a specific physical display
Digitizer grid disconnect
area.
There are shorted lines. Pen or touch may be malfunctioning in a specific physical display area.
Digitizer channel
There is an unbalanced channel. Pen or touch may be malfunctioning in a specific physical display
degraded
area.
Digitizer calibration
The calibration capacitor in a certain channel is set to minimal or maximum value. Pen or touch
degraded
may be malfunctioning in a specific physical display area.
Internal Firmware Error
Firmware resource problem in executing diagnostics. Diagnostics tool is not functional.
Device Error
Critical malfunction was detected, test cannot continue.
Host Timeout Error
Host communication or resources problem in executing diagnostics.
Hardware calibration is
Hardware calibration is required to gain maximum performance.
required
Symptoms