therefore the lowest acoustical output for any configuration (components installed), operating
condition (applications being run), and ambient temperature. Because acoustical output is
dependent and indeed minimized for each combination of these variables, no single acoustical level
(sound pressure level or sound power level) represents the M1000e, and instead boundaries on sound
power level are provided below:
Lowest Fan Speed: Upper Limit A-weighted Sound Power Level, LwA-UL, is 7.5 bels
Full Fan Speed: Upper Limit A-weighted Sound Power Level, LwA-UL, is 9.7 bels
LwA-UL is the upper limit sound power level (LwA) calculated per section 4.4.2 of ISO 9296
(1988) and measured in accordance to ISO 7779 (1999)
Acoustical models have been provided to predict performance between these bounds in the
ESSA tool: http://solutions.dell.com/DellStarOnline/Launch.aspx/ESSA
A few things to be aware of:
Fans are loud when running at full speed. It is rare that fans need to run at full speed. Please
ensure that components are operating properly if fans remain at full speed.
The CMC will automatically raise and lower the fan speed to a setting that is appropriate to
keep all modules cool.
If a single fan is removed, all fans will be set to 50% speed if the enclosure is in Standby
mode; if the enclosure is powered on, removal of a single fan is treated like a failure (nothing
happens).
Re-installation of a fan will cause the rest of the fans to settle back to a quieter state.
Whenever communication to the CMC or iDRAC is lost such as during firmware update, the fan
speed will increase and create more noise.