Maintenance Menu; Items In The Maintenance Menu - Sony PDW-F1600 Operation Manual

Professional disc recorder
Hide thumbs Also See for PDW-F1600:
Table of Contents

Advertisement

Maintenance Menu

Items in the maintenance menu

The following tables show the items in the maintenance
menu.
• Item names are the names which appear on the video
monitor of this unit and an external monitor to which the
output of the COMPOSITE OUTPUT 2 (SUPER)
connector, the SDSDI OUTPUT 2 (SUPER) connector,
or the HDSDI OUTPUT 2 (SUPER) connector is input.
An abbreviated name appears in the time data display
area when you press the NEXT button.
Item
M30: SOFTWARE VERSION
M31: SERIAL NUMBER
M33: FILE I/F
PROAV DISPLAY
CONFIG
PC REMOTE
M36: HOURS METER RESET
M37: AUDIO
M370: HEAD ROOM
CONFIG
M371: DATA LEN
M372: NON-AUDIO
INPUT
Sub-Item
1
2
3
4
M373: INPUT LEVEL
Sub-Item
1
2
M377: OUTPUT LEVEL
148
Maintenance Menu
M3: OTHERS: Other setting items
Setting
Display of the software version of this unit
Display of the serial number of this unit
Selects whether or not to display PROAV directory.
DISABLE: Do not display PROAV directory.
ENABLE: Display PROAV directory.
Disables or enables a FAM connection.
ENALBE: Enable a FAM connection.
F-KEY SELECT: Enable or disable a FAM connection using the function menu.
Display and reset of the hours meter and the thread counter
Select the audio reference level (headroom).
–20dB, –18dB, –16dB, –12dB, EBUL
Note
EBUL can be selected only when the system frequency is 50i/50P/25P.
Select the audio channel configuration for IMX recording.
16bit × 8ch: 16-bit, 8-channel configuration
24bit × 4ch: 24-bit, 4-channel configuration
Select whether to handle digital audio signals as non-audio signals during
recording.
Audio (audio): Handle as linear PCM audio signals.
data: Handle as non-audio signals.
Tr1/Tr2
Tr3/Tr4
Tr5/Tr6
Tr7/Tr8
Set the upper limit for the signal level input to audio channels 1/3 or 2/4.
+4dB, 0dB, –3dB, –6dB, EBUL
CH1/CH3
Note
CH2/CH4
EBUL can be selected only when the system frequency is 50i/50P/25P.
Set the reference level for audio output signals.
+4dB, 0dB, –3dB, –6dB, EBUL
Note
EBUL can be selected only when the system frequency is 50i/50P/25P.
• The values in the Settings columns are the values which
appear in the time data display area. (The values may
appear in a different format on an external monitor. In
this case, the external monitor values are shown in
parentheses.) Underlined values are the factory defaults.
This manual does not explain the menu items in M0:
CHECK, M1: ADJUST, M2: SERVICE SUPPORT, and
M6: DRIVE. Refer to the Maintenance Manual for an
explanation of these items.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pdw-hd1500

Table of Contents