poweron(8)
EXAMPLES
108
SPARC Enterprise Mx000 Servers XSCF Reference Manual • Last Revised August 2009
When the poweron(8) command is executed, power-on results for each of the
specified domains are displayed in the following format:
The power was turned on normally.
Powering on
Not Powering on An error occurred, and the power could not be turned on. An
error message is displayed with Not Powering on.
The showdomainstatus(8) command can be used to check whether the power
of each domain on the system is on.
Turns on power to all domains.
EXAMPLE 1
poweron -a
XSCF>
DomainIDs to power on:00,01,02,03
y
Continue? [y|n]:
00:Powering on
01:Powering on
02:Powering on
03:Powering on
*Note*
This command only issues the instruction to power-on.
The result of the instruction can be checked by the "showlogs power".
Turns on power to domains with domain IDs 0.
EXAMPLE 2
poweron -d 0
XSCF>
DomainIDs to power on:00
y
Continue? [y|n]:
00:Powering on
*Note*
This command only issues the instruction to power-on.
The result of the instruction can be checked by the "showlogs power".
Turns on power to domains with domain IDs 0. Automatically replies with
EXAMPLE 3