VISCA Camera-Issued Messages
ACK/Completion Messages
ACK
Completion
z = Device address + 8

Error Messages

Syntax Error
Command Buffer Full
Command Canceled
No Socket
Command Not Executable
z = Device address + 8
Network Change Message
Network Change
z = Device address + 8
Command Messages
Comments
z0 4y FF
Returned when the command is accepted.
(y:Socket No.)
z0 5y FF
Returned when the command has been executed.
(y:Socket No.)
Command Messages
Comments
z0 60 02 FF
Returned when the command format is different or when a command with illegal
command parameters is accepted.
z0 60 03 FF
Indicates that two sockets are already being used (executing two commands) and the
command could not be accepted when received.
z0 6y 04 FF
Returned when a command which is being executed in a socket specified by the
(y:Socket No.)
cancel command is canceled. The completion message for the command is not
returned.
z0 6y 05 FF
Returned when no command is executed in a socket specified by the cancel
(y:Socket No.)
command, or when an invalid socket number is specified.
z0 6y 41 FF
Returned when a command cannot be executed due to current conditions. For
(y:Execution command
example, when commands controlling the focus manually are received during auto
Socket No. Inquiry
focus.
command:0)
Command Message
Comments
z0 38 FF
Issued when power is being routed to the camera, or when the VISCA device is
connected to or disconnected from the VISCA OUT connector.