PPP to Frame Relay Bypass
Application Description
This application provides a permanent connection between the PPP port and the
Frame Relay Station. The Frame Relay Station uses the Control Protocol Support
ANSI T1.617 Annex D. The Station's DLCI number is automatically learned to
allow for added flexibility.
Configuration Summary
Port #1 FRI Bypass, ext clk, Annex D, 2 Auto- learn DLCI stations
Port #2 PPP RFC1490 encapsulation, 57600 bps, VJ compression
Port #3 PPP RFC1490 encapsulation, 57600 bps, VJ compression
FRI Port #1 Station 1 connects to PPP Port #3 (FRI-1s1 - PPP-3)
FRI Port #1 Station 2 connects to PPP Port #2 (FRI-2s2 - PPP-2)
CTP access via CTP switch.
Optional Application CMEMs
V1000001.MEM Standard application as mentioned in Summary
V1000001.001 Port #2 PAD, CTP access via PAD or switch.
V1000001.002 Port #1 PPP, Port #2 FRI, (FRI-2s2 - PPP-1)
V1000001.003 Port #1 PAD, Port #2 FRI
V1000001.004 Port #1 NULL (no daughter card), Port #2 FRI
V1000001.005 Port #1 X.25, Port #2 FRI (ISDN Perm B1)