Removing And Reinstalling The Left Cage - Lenovo ThinkServer RD430 Hardware Maintenance Manual

Hardware maintenance manual - thinkserver rd430
Hide thumbs Also See for ThinkServer RD430:
Table of Contents

Advertisement

Attention: For proper cooling and airflow, reinstall the cooling shroud before turning on the server. Operating
the server with the cooling shroud removed might damage server components.

Removing and reinstalling the left cage

Attention: Do not open your server or attempt any repair before reading and understanding "Safety information"
on page iii and "Guidelines" on page 81.
This topic provides instructions on how to remove and reinstall the left cage. For more information about the
left cage, see "Front view of server models with 2.5-inch hard disk drive bays" on page 20.
Note: This topic applies only to server models with 2.5-inch hard disk drive bays.
For server models with 2.5-inch hard disk drive bays, you need to remove the left cage before handling the
front panel board, the front VGA DB-15 connector, and the diagnostic module.
Before you begin, print all the related instructions or ensure that you can view the PDF version on another
computer for reference.
Note: Depending on the model, your server might look slightly different from the illustrations in this topic.
To remove and reinstall the left cage, do the following:
1. Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all
power cords from electrical outlets and disconnect all cables that are connected to the server.
2. If the server is installed in a rack cabinet, remove the server from the rack cabinet and place it on a flat,
clean, and static-protective surface. See the Rack Installation Instructions that comes with the server.
3. Remove the server cover. See "Removing the server cover" on page 83.
4. Remove the front bezel. See "Removing and reinstalling the front bezel" on page 85.
5. Remove the cooling shroud. See "Removing and reinstalling the cooling shroud" on page 91.
6. If your server has a slim optical drive installed, disconnect the signal cable and the power cable from the
rear of the slim optical drive.
7. Record the cable routing and cable connections and then disconnect the front panel cable, the front
panel USB cable, the diagnostic module cable, and the cable for the front VGA DB-15 connector from
the system board. Then, release the cables from any cable clips or ties in the chassis.
.
Chapter 6
Installing, removing, or replacing hardware
93