4.6.5.6 Timer & Protect Page; Inactivity Time Multiplier Value - Fujitsu MCE3064AP Product Manual

Fujitsu computer drive user manual
Table of Contents

Advertisement

4.6.5.6 Timer & protect page
Bit
7
Byte
0
PS
1
2
3
4
5-7
Inactivity Time Multiplier indicates the minimum time from the end of an access command until
the ODD enters standby mode. Table 4.66 lists the relationship between the specified value and
time. When a value of X'1' to X'9' is specified, the command assumes X'A' and responds with
Recovered Error.
Inactivity Time
Multiplier
0h
1h
2h
3h
4h
5h
6h
7h
8h
9h
Ah
Bh
Ch
Dh
Eh
Fh
Table 4.66 Timer & protect page
6
5
4
0
Page Length (06h)
Reserved
Reserved
Reserved
Reserved
Table 4.67 Inactivity Time Multiplier value
Minimum time after the end of an access command until the ODD
C156-E142-02EN
3
2
Page Code (1Ch)
Inactivity Time Multiplier
enters standby mode.
Infinite
125 ms
250 ms
500 ms
1 s
2 s
4 s
8 s
16 s
32 s
1 min
2 min
4 min
8 min
16 min
32 min
1
0
DISP
SWPP
4 - 51