Initialization (Reset)/Functional Restriction Setting (FUNCTION)

You can return the settings to their factory-preset values and
restrict operations.
1. Hold down the [MENU/ENTER] button and [INPUT/RETURN]
button at the same time until "F" appears in the screen, and
then press the [MENU/ENTER] button and [VOL-/
at the same time while "F" appears.
FUNCTION
ALL RESET
ADJUSTMENT LOCK
RS-232C
OSD DISPLAY
LED
TEMPERATURE ALERT
STATUS ALERT
OK...[ENTER]
2. Select and set the items.
ALL RESET
Resets the settings to the factory default settings.
Select ALL RESET, and then press [MENU/ENTER] button.
After initialization, turn the main power switch off and then
back on.
ALL RESET ..............Resets all the settings to the factory default
settings.
CANCEL ..................Go back without resetting.
ADJUSTMENT LOCK
You can disable operations on the monitor buttons.
OFF.......Enables operation.
ON 1.....Disables all operations other than turning power
on/off and FUNCTION.
ON 2.....Only the FUNCTION operation is enabled.
Disables all operations other than FUNCTION
(not even power on/off ).
RS-232C
Specifies whether to allow control via RS-232C.
(See page 24.)
OSD DISPLAY
Shows/hides the menu, modes and messages.
The FUNCTION screen cannot be hidden.
ON 1......................Shows all menus, modes and messages.
ON 2......................Hides messages automatically displayed
by the display. Shows messages during
operation.
OFF........................Hides all menus, modes and messages.
LED
Specifies whether to light the power LED.
] button
OFF
UNLOCKED
ON 1
ON
OFF
OFF
END...[RETURN]
3. Press [INPUT/RETURN] button to return to the normal
NOTE:
• When both abnormal temperature and hardware error are
• If TEMPERATURE ALERT or STATUS ALERT is set to OSD & LED,
• If TEMPERATURE ALERT or STATUS ALERT is set to LED or OSD &
TEMPERATURE ALERT
Selects the notification method for an abnormal
temperature.
OFF......................Do not notify about an abnormal
temperature.
OSD & LED ........When an abnormal temperature is detected,
the power LED flashes in red and green
alternately and the screen displays a
message: TEMPERATURE.
LED ......................When an abnormal temperature is detected,
the power LED flashes in red and green
alternately.
STATUS ALERT
Selects the notification method for a hardware error.
OFF......................Do not notify about the error.
OSD & LED ........When a hardware error is detected, the power
LED flashes in red and the screen displays a
message: STATUS [xxxx].
LED ......................When a hardware error is detected, the power
LED flashes in red.
screen.
detected, the hardware error notification overrides.
alert messages will appear even if the OSD DISPLAY is set to ON
2 or OFF.
LED, the LED lights even if the LED function is set to OFF.