NEC Express5800 series User Manual page 35

Esmpro alertmanager
Hide thumbs Also See for Express5800 series:
Table of Contents

Advertisement

[Manager (TCP/IP In-Band)] dialog
– [IP address (or host name)]:
An IP address (or host name) of the remote Manager is set.
Make sure to specify the IP address of the remote Manager.
NOTE:
If the remote Manager to be set has already been specified as
the trap destination of the SNMP service, release the trap destination
setting of the SNMP service.
NOTE:
Exercise the care to avoid duplicate setting of the same IP
address (or host name) for the trap destination of the SNMP service
after this setting.
If duplicate setting is made, more than one alert will be reported.
– [Port number]:
The port number used for the communication between sockets can be set.
For this number, the same value must be set to the Agent and remote Manager (the
default value is 31134 for both Agent and remote Manager).
Do not change the value as long as the default value works.
Using the Alert Manager
31