Timer On/Off On-Off Operation; Health Airflow Operation - Haier HSU12 Service Manual

Wall mounted type dc inverter e-series
Table of Contents

Advertisement

Set clock correctly before starting TIMER operation.
1.After unit starts, select your desired operation mode.
2.Press TIMER button to change TIMER mode. Every
time the button is pressed, display changes as follows:
Remote controller:
TIMER ON
TIMER OFF
Then select your desired TIMER mode (TIMER ON or
TIMER OFF or TIMER ON-OFF). "
3.Press HOUR
It can be adjusted within 24 hours.
4.After setting correct time, press SET button to confirm
"
"or"
" on the remote controller stops flashing.
5.Cancel TIMER mode
Just press TIMER button several times until TIMER mode
disappears.
Hints:
After replacing batteries or a power failure happens, time
setting should be reset.
Remote controller possesses memory function,when use
TIMER mode next time, just press SET button after mode
selecting if time setting is the same as previous one.
According to the Time setting sequence of TIMER ON or
TIMER OFF, either Start-Stop or Stop-Start can be
achieved.
1.Press ON/OFF to starting
Setting the comfort work conditions.
2.The setting of health airflow function
1).Press the button of health airflow ,
display
. Horizontal airflow sending. Avoid the strong
airflow
blows direct to the body.
2).Press the button of health airflow again,
the displa y . Downward airflow sending. Avoid the strong
airflow blows
direct to the body.
3.The cancel of the health airflow function
Press the button of health airflow again, the unit
working under the condition before the setting of health
airflow function.
Notice: Cannot pull direct the flap by hand. Otherwise, the
grille will run incorrectly. If the grille is not run correctly, stop
for a minute and then start, adjusting by remote
controller.
Note:
1.After setting the health airflow function, the position
grill is fixed.
2.In heating, it is better to select the
3.In cooling, it is better to select the
4.In cooling and dry, using the air conditioner for a long
time under the high air humidity, a phenomenon falling
water occurs at the grille .
drips of
Operation
BLANK
TIMER ON-OFF
"or "
"will flash.
button to set time.
appears on the
appears on
goes on
mode.
mode.
HSU12/18VHJ(DB)
IMPORTANT INFORMATION REGA-
RDING THE REFRIGERANT USED
This product contains fluorinated greenhouse gases covered by
the Kyoto Protocol. Do not vent into the atmosphere.
Refrigerant type:R410A
GWP* value:1975
GWP=global warming potential
Please fill in with indelible ink,
• 1
the factory refrigerant charge of the product
• 2
the additional refrigerant amount charged in the field and
• 1+2 the total refrigerant charge
on the refrigerant charge label supplied with the product.
The filled out label must be adhered in the proximity of the product
charging port (e.g. onto the inside of the stop value cover).
A contains fluorinated greenhouse gases covered by the Kyoto
Protocol
B factory refrigerant charge of the product: see unit name plate
C additional refrigerant amount charged in the field
D total refrigerant charge
E outdoor unit
F refrigerant cylinder and manifold for charging
50
system configration
Contains fluorinated greenhouse gases
covered by the Kyoto Protocol
R410A
1=
2
2=
1
1+2=
F
E
A
kg
B
kg
C
kg
D