Check Operation; Leveling The Range - Frigidaire 318201679 (0903) Installation Instructions Manual

30" dual fuel slide-in range models with an electric oven and a gas cooktop
Table of Contents

Advertisement

Available languages

Available languages

30" DUAL FUEL SLIDE-IN RANGE INSTALLATION INSTRUCTIONS
9.

Leveling the Range -

Level the range and set cooktop height before
installation in the cut-out opening.
1. Install an oven rack in the center of the oven.
2. Place a level on the rack (see figure 12). Take 2
readings with the level placed diagonally in one
direction and then the other. Level the range, if
necessary, by adjusting the 4 leg levelers with a
wrench.
3. Taking care to not damage the countertop, slide
range into cut-out opening and double check for
levelness.
Figure 12
10.

Check Operation

Refer to the Use and Care Guide packaged with the
range for operating instructions and for care and
cleaning of your range.
Do not touch the elements or burners. They may be hot
enough to cause burns.
Remove all packaging from the oven before testing.
1. Install Burner Caps and Grates
This range is equipped with sealed burners as
shown (see Figure 13).
1. Remove all packaging material.
2. Discard the packaging material (if needed).
3. Install the burner grates and burners caps on the unit
burners.
NOTE: There are no burner adjustments necessary on
this range.
2. Turn on Electrical Power and Open Main Shutoff
Gas Valve
3. Check the Igniters
Operation of electric igniters should be checked after
range and supply line connectors have been carefully
checked for leaks and range has been connected to
electric power. To check for proper lighting:
1. Push in and turn a surface burner knob to the LITE
position. You will hear the igniter sparking.
2. The surface burner should light when gas is available
to the top burner. Each burner should light within
four (4) seconds in normal operation after air has been
purged from supply lines. Visually check that burner
has lit.
3. Once the burner lights, the control knob should be
rotated out of the LITE position.
There are separate ignition devices for each burner. Try
each knob separately until all burner valves have been
checked.
(Models with an Electric Oven and a Gas Cooktop)
4. Adjust the "LOW" Setting of Surface Burner
Valves (see Figure 13)
a. Push in and turn each control to LITE until burner
ignites.
b. Quickly turn knob to LOWEST POSITION.
c. If burner goes out, readjust valve as follows:
Reset control to OFF. Remove the surface burner
control knob, insert a thin-bladed screw driver into the
hollow valve stem and engage the slotted screw inside.
Flame size can be increased or decreased with the
turn of the screw. Adjust flame until you can quickly
turn knob from LITE to LOWEST POSITION without
extinguishing the flame. Flame should be as small as
possible without going out.
5. Adjust the "LOW" setting of the dual valve (Fig. 14)
Note: On the dual valve the low setting of each portion
should be adjusted individually.
a. Push in and turn control to LITE until the rear portion
of the bridge burner ignites only.
b. Quickly turn knob to LOWEST POSITION.
c. If burner goes out, reset control to OFF.
d. Remove the surface burner control knob.
e. The rear portion of the bridge burner flame size can
be increased or decreased with the turn of the screw
A. Use screw B to adjust the flame size of the center
portion of the bridge burner. Turn counterclockwise
the screw to increase flame size. Turn clockwise the
screw to decrease flame size. Adjust flame until you
can quickly turn knob from LITE to LOWEST POSITION
without extinguishing the flame. Flame should be as
small as possible without going out.
Note: Air mixture adjustment is not required on surface
burners.