5. SYSTEM PARAMETERS
Parameter
Function
P041
Fixed frequency 1 (Hz)
P042
Fixed frequency 2 (Hz)
Fixed frequency 3 (Hz)
P043
P044
Fixed frequency 4 (Hz)
P045
Inversion fixed setpoints for
fixed frequencies 1 - 4
P046
Fixed frequency 5 (Hz)
P047
Fixed frequency 6 (Hz)
P048
Fixed frequency 7(Hz)
P050
Inversion fixed setpoints for
fixed frequencies 5 - 7
© Siemens plc 1997
Range
Description / Notes
[Default]
0 - 400.00
Valid if P006 = 2 and P053 = 6 or 18.
[5.00]
0 - 400.00
Valid if P006 = 2 and P052 = 6 or 18.
[10.00]
0 - 400.00
Valid if P006 = 2 and P051 = 6 or 18.
[15.00]
0 - 400.00
Valid if P006 = 2 and P051 = P052 = P053 = 17 .
[20.00]
0 - 7
Sets the direction of rotation for the fixed frequency:
[0]
P045 = 0
P045 = 1
P045 = 2
P045 = 3
P045 = 4
P045 = 5
P045 = 6
P045 = 7
0 - 400.00
Valid if P006 = 2 and P051 = P052 = P053 = 17.
[25.00]
0 - 400.00
Valid if P006 = 2 and P051 = P052 = P053 = 17.
[30.00]
0 - 400.00
Valid if P006 = 2 and P051 = P052 = P053 = 17.
[35.00]
0 - 7
Sets the direction of rotation for the fixed frequency:
[0]
P050 = 0
P050 = 1
P050 = 2
P050 = 3
P050 = 4
P050 = 5
P050 = 6 or 7
25
FF 1
FF 2
Fixed setpoints not inverted.
Fixed setpoints inverted.
FF 5
FF 6
Fixed setpoints not inverted.
Fixed setpoints inverted.
English
FF 3
FF4
FF 7