When Device Cannnot Be Detected Automatically By
Node Registration
When the utility software cannot automatically detect the device, check the following.

When Device Does Not Start

Check Power LED

GN-1010 User's Manual — Troubleshooting
Check the connection between the device and PC which executes the utility soft-
ware, referring to the section "Connecting between the GN-1010 and PC" (P.18).
Check the DIP switch setting.
When the PC which executes the utility software is the DHCP client, exit the soft-
ware. When approx. 1 minute has passed, open the software again.
Check that the power LED is on.
<When extinguished>
Check if the AC adapter is correctly plugged into the power supply con-
nector and an outlet.
Check if the power supply switch is in "DC" side.
Check whether or not the power LED is flashing.
<When flashing>
If the power LED is still flashing more than 10 minutes after the power is
turned on, the problem may be a device firmware failure. Use the utility soft-
ware to upgrade the firmware version.