Download Print this page

Frigidaire 318201463 (0711) Installation Instructions Manual page 4

Models with optional electric built-in oven combination

Advertisement

Available languages

Available languages

GAS COOKTOP INSTALLATION INSTRUCTIONS
All mounting hardware
must be used to secure
the built-in oven to the
cabinets. Refer to the
built-in oven installa-
tion instructions.
208/240 Volt grounded
junction box for built-in
oven.
* If no cooktop is installed directly over
the oven unit, 5" (12.7 cm) maximum
is allowed.
** 32" (81.3 cm) min. from top of cabinet
to top of runners must be maintained.
Figure 3 – TYPICAL UNDER COUNTER INSTALLATION OF AN ELECTRIC BUILT-IN OVEN
(Models with Optional Electric Built-In Oven Combination)
This cooktop may be in-
stalled over certain built-
in electric oven models.
Approx. 3"
(7.6 cm)
G
4 ½" Max.*
(11.4 cm Max.*)
MODEL
27" (68.6 cm)
Wall Oven
30" (76.2 cm)
Wall Oven
WITH COOKTOP MOUNTED ABOVE
Side filler panels are necessary to isolate the
unit from adjoining cabinets. Panel height
should allow for installation of approved
cooktop models. See "Typical Gas Cooktop In-
stallation Over an Electric Built-in Oven Installed
Under the Counter" in this booklet.
36" Min.
(91.4 cm Min.)
E
F
Use ¾" (1.9 cm) plywood, installed on two
runners, flush with toe plate. Must be capable
of supporting 150 lbs (68 kg).
Cut an opening in wood base mini-
mum 9" x 9" (22.9 cm X 22.9 cm),
2" (5.1 cm) from left side filler
panel, to route armoured cable to
junction box.
CUTOUT DIMENSIONS
E. HEIGHT
28
1
/
" (71.4 cm) Min.
24
8
28
5
/
" (72.7 cm) Max.
25 ¼" (64.1 cm) Max.
8
28 ¼" (71.8 cm) Min.
28 ½" (72.4 cm) Min.
28
7
/
" (73.3 cm) Max.
29" (73.7 cm) Max.
8
4
32" Min.**
(81.3 cm Min.**)
F. WIDTH
G. DEPTH
7
/
" (63.2 cm) Min.
8
23 ½"(59.7 cm)
24" (61 cm)

Advertisement