Release M.10.66 - HP ProCurve Series 3400cl Release Notes

Procurve series
Hide thumbs Also See for ProCurve Series 3400cl:
Table of Contents

Advertisement

Software Fixes in Release M.08.51 - M.10.72

Release M.10.66

Authentication (PR_1000454714) — Concurrent 802.1X and MAC Authentication does
not give the 802.1X value precedence. This fix gives 802.1X VLAN assignment precedence
over MAC Auth RADIUS VLAN assignment.
Web Management (PR_1000760153) — A Java error occurs when viewing "Stack
Closeup" in the Web Management interface. Only a blank screen is displayed.
DHCP Snooping (PR_1000469934) — When DHCP Snooping is enabled and configured,
and a client sends a "DHCPINFORM" after receiving address information, the DHCP server
response is not forwarded to the client by the switch.
IDM/DIPLD (PR_1000784427) — The IDM feature that allows RADIUS-assigned ACLs for
802.1X clients was incorrectly enabled to support DIPLD CLI commands.
RADIUS/Jumbo (PR_ 1000779048) — When an 802.1X enabled port belongs to a VLAN
that is jumbo enabled, the Access-Request will specify a value of Framed-MTU of 9182 bytes.
When the RADIUS server replies with a large frame, the switch does not respond, causing
the authentication process to halt.
Crash (PR_0000001756) — Some SNMP set commands may cause the switch to crash
with a message similar to the following.
Software exception at bcmHwVlans.c:149 -- in 'mAdMgrCtrl', task
ID=0x18636e8 -> ASIC call failed: Entry not found.
Crash (PR_0000002433) — A certain sequence of CLI commands may cause the switch
to crash with a message similar to the following.
Software exception at dsnoop_ctrl.c:109 -- in 'mDsnoop002'.
Enhancement (PR_0000001316) — The MSTP VLAN Assignment is enhanced. For more
information, see
"Release M.10.65 Enhancements" on page
Config (PR_0000002077) — Upload of configuration files fails when the spanning-tree CLI
command is present in the config file.
VLAN (PR_0000002103) — The alteration of the VLAN/MSTP instance mapping in the
pending configuration is not functioning properly. Any attempt to remove a single VLAN ID
(VID) from one MSTP instance and then assign it to another MSTP instance fails, though
specifying a VID range succeeds.
Release M.10.66
Problems Resolved in Release M.10.66 (Not a Public Release)
UDLD (PR_0000002473) — UDLD protocol packets received on a (non-UDLD) trunk port
are incorrectly forwarded out of the same port from which they are received, resulting in
high CPU usage on the switch.