Release M.08.78; Release M.08.79; Release M.08.80; Release M.08.81 - HP ProCurve Series 3400cl Release Notes

Procurve series
Hide thumbs Also See for ProCurve Series 3400cl:
Table of Contents

Advertisement

Release M.08.78

Problems Resolved in Release M.08.78 (Not a general release)
Enhancement (PR_1000291806) — Fast boot enhancement.
MSTP (PR_1000286883) — Slow MSTP fail-over and fall-back time.

Release M.08.79

Problems Resolved in Release M.08.79 (Not a general release)
Fault (PR_1000089786) — Chassis fault LED stops blinking after a new OS image was
downloaded to the switch.
Ports (PR_1000090867) — The dual personality ports (RJ-45 and mini-GBIC) lose state
(running speed) after being hot swapped in or out.
Enhancement (PR_100292455) — Rate display for ports on CLI. New command: "show
interface port-utilization", not available on Menu nor Web Interface.

Release M.08.80

Problems Resolved in Release M.08.80 (Never released)
RSTP (PR_1000297195) — The switch repeatedly flushes its MAC address table, resulting
in intermittent flooding of all traffic.

Release M.08.81

Problems Resolved in Release M.08.81 (Not a general release)
XRRP (PR_1000291250) — When a XRRP router is rebooted and activates its virtual MAC
address, it incorrectly transmits ARP requests, which fails to update forwarding tables and
ARP caches.

Release M.08.82

Problems Resolved in Release M.08.82 (Not a general release)
Meshing (PR_1000300165) — Packets larger than 1482 bytes within a mesh will be
reported as FCS receive errors and may generate excessive CRC error messages in the event
log.