6. Adjust the Object size, History and Sensitivity profile sliders (see table below for details). Any detected
motion within an active window is then indicated by red peaks in the Activity window (the active
window has a red frame).
7. Click Save.
If there are parts of the Include window that you wish to exclude, click the
Configure Excluded Windows radio button and repeat steps 1-8 above.
Please see the online help
Parameter
Size
High
Only very large objects
trigger motion detection
Low
Even very small objects
trigger motion detection
Default val-
Low
ues
Examples:
• Avoid triggering on small objects in the image by selecting a high size level.
• To trigger motion detection as long as there is activity in the area, select a high history level.
• To only detect flashing light, low sensitivity can be selected. In other cases, a high sensitivity level is recommended.

Port Status

Under Event Configuration > Port Status there is a list that shows the status for the connected inputs and
outputs of the AXIS 213 PTZ for the benefit of the Operator who cannot access the System Options section.
Example:
If the Normal state for a push button connected to an input is set to Inactive - as long as the button is not pushed, the state
is inactive. If the button is pushed, the state of the input changes to active.
for descriptions of options.
History
An object that appears in the region
triggers the motion detection for a long
period
An object that appears in the region
triggers motion detection for only a
very short period
Medium to High
AXIS 213 PTZ
Sensitivity
Ordinary colored objects against ordi-
nary backgrounds trigger the motion
detection
Only very bright objects against a dark
background trigger motion detection
Medium to High