T8631A,R can be connected to Honeywell's TotalHome
system for external access and control. TotalHome system
devices communicate using HBus, a Honeywell communi-
cations protocol.
These thermostats, powered directly from the control
transformer, provide energy saving control for a 24 Vac
conventional heating/cooling or multistage heat pump
heating/cooling system as indicated in Table 1.
As long as AC power is continuously available to the
transformer, the thermostat will be compatible with most
control systems.
The T8631A,R models include a SYSTEM LED near
the top of the thermostat face. The SYSTEM LED lights
when the thermostat is signaling for heating or cooling.
Thermostat
T8631A
T8631R
WHEN INSTALLING THIS PRODUCT...
1. Read these instructions carefully. Failure to follow
them could damage the product or cause a hazardous
condition.
2. Check the ratings on the product to make sure the
product is suitable for your application.
3. Installer must be a trained, experienced service tech-
nician.
4. After installation is complete, check out product
operation as provided in these instructions.
5. Allow thermostat to warm to room temperature
before operating.
IMPORTANT: After wiring is complete, push excess wire
back into the hole, and plug hole with nonhardening
caulk, putty or insulation to prevent drafts from
affecting thermostat operation.
LOCATION
Install thermostat and subbase about 5 ft [1.5 m] above
the floor in an area with good air circulation at room
temperature.
Do not install the thermostat where it may be affected by:
— drafts or dead spots behind doors, in corners or under
cabinets.
— hot or cold air from ducts.
— radiant heat from sun or appliances.
— concealed pipes and chimneys.
T8631A,R Communicating
Chronotherm III Thermostats
Application
TABLE I—THERMOSTAT MODELS.
Stages
Heat
Cool
1
1
2
1
Installation
J.H . • Rev. 3-93 • © Honeywell Inc. 1993 • Form Number 69-0689—2
T8631R includes AUX. HT. and EM. HT LEDs near the
bottom center of the subbase. The AUX. HT. LED lights
whenever the thermostat is calling for operation of the
backup or auxiliary heater. Backup (auxiliary) heat is more
expensive to operate than the heat pump and typically is
used only when the heat pump is unable to handle the load.
The EM. HT. LED lights whenever the thermostat system
switch is in the EM. HT. position. The EM.HT. LED may
also light on some systems if the heat pump is malfunction-
ing. The system switch needs to be moved to EM.HT. on
these heat pumps.
Heat and cool anticipation is fixed in both models; no
adjustment is necessary. T8631A has adjustable cycle rate
for heating; T8631R cycle rate is adjustable only for
auxiliary heat.
Switching
System
HEAT-OFF-COOL
EM. HT.-HEAT-OFF-COOL
— unheated (uncooled) areas behind the thermostat,
such as an outside wall.
WIRING TO HEATING/COOLING SYSTEM
The T8631 requires connection to both sides of the
heating transformer secondary for power.
If Replacing An Existing Thermostat
Turn off power to thermostat at furnace or heat pump.
A two-transformer system may require turning off two
switches or disconnects. Remove any existing wallplate or
subbase from wall. Label each wire with, or write down,
the letter or number on the wiring terminal as the wire is
removed, to avoid miswiring later.
If New Installation
Run cable to a hole at the selected wall location, and
pull about 3 in. [76 mm.] of wire through the opening.
Color-coded, 18-gauge thermostat cable with one conduc-
tor for each wiring terminal, excluding H terminals, is
recommended. Good service practice recommends select-
ing cable with one or two more conductors than the
immediate application requires.
WIRING TO TOTALHOME SYSTEM
The HBus connection requires an unshielded cable with
3 twisted pairs of #22 AWG solid wire. Use Belden #8742,
Alpha #1304 or equivalent wire. Route this cable with the
thermostat cable to the utility room. Do not connect the
HBus cable to the T8631 until the other TotalHome devices
are connected.
Fan
Program
ON-AUTO
5-1-1
ON-AUTO
5-1-1

Advertisement

loading

Summary of Contents for Honeywell T8631A

  • Page 1 Do not connect the — radiant heat from sun or appliances. HBus cable to the T8631 until the other TotalHome devices — concealed pipes and chimneys. are connected. J.H . • Rev. 3-93 • © Honeywell Inc. 1993 • Form Number 69-0689—2...
  • Page 2: Mounting Subbase

    MOUNTING SCREWS (2) SUBBASE SWITCH UP DISCONNECTS THE HBUS. FAN CAN BE SET FOR ELECTRIC HEAT OR CONVENTIONAL. M3060 M3061 Fig. 3—T8631A 1-stage heat/1-stage cool thermostat with HEAT-OFF-COOL system and ON-AUTO fan switching. (HOT) POWER SUPPLY HEATING SYSTEM TRANSFORMER SWITCH...
  • Page 3 Fig. 4—T8631A 1-stage oil heat/1-stage cool. Oil Primary has its own transformer. HEATING-COOLING WALLPLATE RELAY COOLING DAMPER/ COOLING CHANGE- OVER HEATING RELAY DAMPER/ COND. (HOT) HEATING EQUIP. CHANGE- OIL PRIMARY OVER (HOT) POWER SUPPLY. PROVIDE DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED.
  • Page 4 RESTRICT back of the thermostat. See Fig. 7. WIRING TO T8631A has a factory-set cycle rate of six cycles per THIS AREA hour in heating and three cycles per hour in cooling. For high efficiency furnaces, it can be necessary to change the cycle rate to the hot water setting.
  • Page 5: Mounting The Thermostat

    The fan will run applied to the thermostat, the display will read 1:00 PM and a short time after equipment shuts off with T8631A unless 32 for a minute or less, followed by 1:00 PM and room fan operation switch set for electric.
  • Page 6 Move the system switch to COOL and the fan switch to 3. Press each key as listed below, and look for re- AUTO. Press COOLER key until the setting is about sponses listed as key is held down and released. 10 F [6 C] below room temperature.
  • Page 7 A four-digit code number will appear when the key is Fourth Digit: Not used. released. The four digits of the code represent the following options: CAUTION First T8631A T8631R Digit Do NOT operate heating until heat pump warmup procedure is followed. Refer to manufacturer’s recommendations.
  • Page 8 Home and Building Control Home and Building Control Honeywell Inc. Honeywell Limited—Honeywell Limitée 1985 Douglas Drive North 740 Ellesmere Road Golden Valley, Minnesota 55422 Scarborough, Ontario M1P 2V9 Printed in Taiwan R.O.C...

This manual is also suitable for:

T8631rChronotherm iii t8631aChronotherm iii t8631r