Chapter 1 - Media Application Server Installation; Input Power; Power Failure Backup; Grounding - Toshiba Strata CIX Installation And Maintenance Manual

Mas release 3
Hide thumbs Also See for Strata CIX:
Table of Contents

Advertisement

Media Application Server Installation
The MAS is a multi-function server that connects through a Network Switch to the Strata CIX
System IP LAN connection.
The MAS operating system is Windows
installed.
The MAS is offered in two physical forms:
Micro MAS - A desktop PC style cabinet
2U MAS - A 2U high, rackmount

Input Power

The MAS requires an input power source of 120 VAC, 50 or 60 Hz, 5.67 amps (max). The MAS is
supplied with a standard 15 Amp power cord with a standard three-prong 120VAC that plugs into
an AC power outlet. The MAS requires a dedicated, properly grounded circuit.

Power Failure Backup

Customer-supplied commercially available UPS systems should be used for power failure backup.

Grounding

The MAS does not need any additional grounding provided the AC outlet is properly grounded.

Connection

The MAS connects to the CIX using a single IP connection through a Network Switch or Router. All
of the feature communications and Voice Mail speech paths are carried by this one connection.
The monitor, keyboard and mouse are customer supplied options. The MAS can be accessed via
the network by using the Windows® XP Remote Desktop feature.
Figure 1 - 1
MAS Connection Block Diagram
Strata CIX MAS Installation 06/09
®
XP. The system is shipped with Service Pack 2 (SP2)
*Monitor
*Key Board
*Mouse
Network Switch
MAS
CIX
LAN
*Optional
1
1-1