Download  Print this page

Mitsubishi Electric FR-A500 Instruction Manual Page 72

Transistorized inverter.
Hide thumbs

Advertisement

Func-
Parameter
tion
Number
Second acceleration/deceleration
44
time
45
Second deceleration time
46
Second torque boost (Note 1)
Second V/F (base frequency) (Note
47
1)
Second stall prevention operation
48
current
Second stall prevention operation
49
frequency
50
Second output frequency detection
52
DU/PU main display data selection
53
PU level display data selection
54
FM terminal function selection
55
Frequency monitoring reference
56
Current monitoring reference
57
Restart coasting time
58
Restart cushion time
59
Remote setting function selection
60
Intelligent mode selection
61
Reference I for intelligent mode
62
Ref. I for intelligent mode accel.
63
Ref. I for intelligent mode decel.
Starting frequency for elevator
64
mode
65
Retry selection
Stall prevention operation level
66
reduction starting frequency
Number of retries at alarm
67
occurrence
68
Retry waiting time
69
Retry count display erasure
70
Special regenerative brake duty
71
Applied motor
72
PWM frequency selection
73
0-5V/0-10V selection
74
Filter time constant
Reset selection/disconnected PU
75
detection/PU stop selection
76
Alarm code output selection
77
Parameter write disable selection
Reverse rotation prevention
78
selection
79
Operation mode selection
Name
Setting Range
0 to 3600 s/
0 to 360 s
0 to 3600 s/0 to 360 s,
9999
0 to 30%, 9999
0 to 400Hz, 9999
0 to 200%
0 to 400Hz, 9999
0 to 400Hz
0 to 20, 22, 23, 24, 25,
100
0 to 3, 5 to 14, 17, 18
1 to 3, 5 to 14,
17, 18, 21
0 to 400Hz
0 to 500A
0, 0.1 to 5 s, 9999
0 to 60 s
0, 1, 2
0 to 8
0 to 500A, 9999
0 to 200%, 9999
0 to 200%, 9999
0 to 10Hz, 9999
0 to 5
0 to 400Hz
0 to 10,101 to 110
0 to 10 s
0 to 15%/0 to 30%/0%
(Note 10)
0 to 8, 13 to 18, 20, 23,
0 to 15
0 to 5, 10 to 15
0 to 8
0 to 3, 14 to 17
0, 1, 2, 3
0, 1, 2
0, 1, 2
0 to 8
63
Minimum
Factory Setting
Setting
Increments
0.1 s/0.01 s
0.1 s/0.01 s
0.1%
0.01Hz
0.1%
0.01Hz
0.01Hz
1
1
1
0.01Hz
0.01A
0.1 s
0.1 s
1
1
0.01A
0.1%
0.1%
0.01Hz
1
0.01Hz
1
0.1 s
0

0.1%
1
24
1
1
1
1
1
1
1
1
PARAMETERS
Refer
Customer
To
<EC Version>
setting
Page:
5 s
75
9999
75
9999
71
9999
73
150%
89
0Hz
89
30Hz
88
0
90
1
90
1
90
60Hz <50Hz>
93
Rated output
93
current
9999
94
1.0 s
94
0
96
0
98
9999
100
9999
100
9999
100
9999
100
0
101
60Hz <50Hz>
82
0
101
1 s
101
0
101
0%
85
0
103
2
104
1
105
1
106
14
106
0
108
0
109
0
110
0
111
4

Advertisement

Table of Contents

Comments to this Manuals

Symbols: 0
Latest comments:
  • Rajesh yadav Nov 23, 2017 01:03:
    electrical controling conction manual
  • TAtang Jan 03, 2017 11:22:
    Jalan sebentar terus muncul E,7 errlor
  • THAI Sep 28, 2015 08:47:
    MANUAL INVERTER MITSUBISHI a100 .thank you very much
  • sandeep Feb 15, 2014 09:20:
    good manual and it is very good to understand the contant of inverter and i lernt many things in this manual