Frequencies set in stop-on-contact control (Pr. 270 = 1 or 3) (In external operation mode)
The following table lists the frequencies set when the input terminals (RH, RM, RL, RT, JOG) are selected
together.
Input Signals
RH
RM
RL
RT
Note: 1. O indicates that the signal is on.
2. Indicates that the remote setting function is not selected. (The remote setting function disables
stop-on-contact control.)
3. The selection of the 12-bit digital speed input option (FR-A5AX) makes the above list invalid.
Note that when both RL and RT are on, the frequency is as set in Pr. 6 and stop-on-contact
control is exercised.
4. The jog frequency has the highest priority.
5. When the terminal functions are changed using Pr. 180 to Pr. 186, the other functions may be
affected. Confirm the functions of the corresponding terminals before making settings.
Set Frequency
JOG
Speed 1 (high speed)
Speed 2 (middle speed)
Speed 3 (low speed)
According to 0-5V, 0-10V, 4-20mA
Jog frequency
Speed 6
Speed 5
Speed 1 (high speed)
Jog frequency
Speed 4
Speed 2 (middle speed)
Jog frequency
Speed 3 (low speed, stop-on-contact
frequency)
Jog frequency
Jog frequency
Jog frequency
Jog frequency
Jog frequency
Speed 3 (low speed, stop-on-contact
frequency)
Jog frequency
Jog frequency
Speed 3 (low speed, stop-on-contact
frequency)
Jog frequency
Speed 6
Speed 7
Jog frequency
Jog frequency
Jog frequency
Jog frequency
Speed 3 (low speed, stop-on-contact
frequency)
Jog frequency
According to 0-5V, 0-10V, 4-20mA
Stop-on-
Contact
Control
Function
Pr. 4
Pr. 5
Pr. 6
Pr. 15
Pr. 26
Pr. 25
Pr. 4
Pr. 15
Pr. 24
Pr. 5
Pr. 15
Pr. 6
Pr. 15
Pr. 15
Pr. 15
Pr. 15
Pr. 15
Pr. 6
Pr. 15
Pr. 15
Pr. 6
Pr. 15
Pr. 26
Pr. 27
Pr. 15
Pr. 15
Pr. 15
Pr. 6
Pr. 6
Pr. 15
*
indicates that the function is selected.
176
PARAMETERS
Remarks
Middle speed when
Pr. 26 = 9999
Low speed when Pr. 25 = 9999
Low speed when Pr. 24 = 9999
Middle speed when
Pr. 26 = 9999
Low speed when Pr. 27 = 9999

Advertisement

Table of Contents

Comments to this Manuals

Symbols: 0
Latest comments:
  • Rajesh yadav Nov 23, 2017 01:03:
    electrical controling conction manual
  • TAtang Jan 03, 2017 11:22:
    Jalan sebentar terus muncul E,7 errlor
  • THAI Sep 28, 2015 08:47:
    MANUAL INVERTER MITSUBISHI a100 .thank you very much
  • sandeep Feb 15, 2014 09:20:
    good manual and it is very good to understand the contant of inverter and i lernt many things in this manual