<Setting>
Refer to the following list and set the parameters:
Pr. 156 Setting
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
Driving
100
Regenerative
Driving
101
(Note 4)
Regenerative
Note: 1. When "Operation not continued for OL signal output" is selected, the "E.OLT" alarm code
(stopped by stall prevention) is displayed and operation stopped.
(Alarm stop display "E.OLT")
2. If the load is heavy, the lift is predetermined, or the acceleration/deceleration time is short, the
stall prevention may be activated and the motor not stopped in the preset acceleration/
deceleration time. Therefore, set optimum values to the Pr. 156 stall prevention operation level.
(When the output voltage reduces during stall prevention operation, an overcurrent trip will be
less liable to occur but the torque decreases. Set "0" in Pr. 154 when the torque may be
reduced.)
3. In vertical lift applications, make setting so the fast-response current limit is not cativated. Torque
may not be produced, causing a drop due to gravity.
4. At the setting of "101", the fast-response current limit can be disabled in the driving mode as
compared to the setting of "100".
Always perform test operation.
Stall prevention operation performed during acceleration may increase the
acceleration time. Stall prevention operation performed during constant speed may
cause sudden speed changes.
Stall prevention operation performed during deceleration may increase the
deceleration time, increasing the deceleration distance.
Stall Prevention Operation Selection
Fast-response
Current Limit
...Activated.
Acceleration
...Not activated
...Activated
...Not activated
Constant
Deceleration
speed
CAUTION
152
PARAMETERS
OL Signal Output
...Operation continued
...Operation not
continued (Note 1)

Advertisement

Table of Contents

Comments to this Manuals

Symbols: 0
Latest comments:
  • Rajesh yadav Nov 23, 2017 01:03:
    electrical controling conction manual
  • TAtang Jan 03, 2017 11:22:
    Jalan sebentar terus muncul E,7 errlor
  • THAI Sep 28, 2015 08:47:
    MANUAL INVERTER MITSUBISHI a100 .thank you very much
  • sandeep Feb 15, 2014 09:20:
    good manual and it is very good to understand the contant of inverter and i lernt many things in this manual