Aiphone GT-AC Installation And Operation Manual page 7

Access control keypad module
Table of Contents

Advertisement

Orange (L)
Input the master code twice.
(Default:
Setting the code length
(Default: 4 digits)
Input the setting code.
Illumination Blinking
Bleep
Inputting of code length (ex.: 5 digits)
4, 5, or 6 digits
Illumination Blinking
Beep
- When the
key is pressed, the green LED lights up, the buzzer beeps twice, and the system exits the setting mode.
(If the
key is included in the user code and the master code, the system does not exit the setting mode.)
- You can continue the setting up operation by entering an arbitrary setting code.
· The set code will be saved in
memory, even if the code length
is changed. However, codes of
different lengths cannot be used.
· When the code length has been
changed, the master code returns
to the default value (if the number
of digits in the code is 4, 5, or 6,
the master code is 1234, 12345,
or 123456 respectively).
Green (R)
)
Setting the master code
(Default 1234)
Input the setting code.
Illumination Blinking
Bleep
Inputting of new master code
(ex.: 4321)
Illumination Blinking
Beep
· Please note that the shift to the
setting mode can be performed
during timer-linked unlocking.
However, if "
" is included in
the master code, the door will
be unlocked, and the shift to
the setting mode will not be
able to be performed.
· The same code cannot be set
for both the user code and the
master code (the previously set
code has priority).
· Do not set simple codes, such
as 1111.
· We recommend that you
change the default master
code.
The result of each operation is indicated by the
lighting up of the LED indicators on the upper section
of the unit, and by the sounding of the buzzer.
(orange)
(green)
Illumination
Blinking
Setting the code
group 1
00 - 59
Inputting of user number (ex.: 01)
When a user code
that has already
been set is selected
Blinks
Illumination
Blinking
Illumination
twice
Bleep,
Bleep
Bleep
Inputting of code (ex.: 1006)
* Numbers 0
-
9 and the
letters A and B can be used
Illumination
Blinking
Beep
· To make the set user code invalid, press 0000 (when 4 digits are
used), 00000 (when 5 digits are used), or 000000 (when 6 digits are
used). Code numbers which contain only "0" cannot be set as user
codes.
· As the factory pre-setting master code is 1234, 1234 (when 4 digits
are used), 12345 (when 5 digits are used), and 123456 (when 6
digits are used) cannot be set as user codes.
· Do not set simple codes, such as 1111.
* The same code cannot be set for both the user code and the
master code. The previously set code has priority.
Bleep, Bleep
group 2
60 - 99
Inputting of user number (ex.: 60)
When a user code
that has already
been set is selected
Blinks
Illumination
Blinking
Illumination
twice
Bleep,
Bleep
Bleep
Inputting of code (ex.: 04B2)
* Numbers 0
-
9 and the
letters A and B can be used
Illumination Blinking
Beep
Indicator
goes out Blinking
Bleep,
Bleep
7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents