302
'...Elements': Same as above except multiplied by number of array
elements per point. Ratio between Total Active Points and Total Active
Points Elements shows how well optimised (or badly like above) with use
of arrays.
Read Callbacks: Number of data postings from CX-Server.
MSecs since last callback: Milliseconds waited since last data.
Min, Max Average Callback interval: Calculation using above values.
Write ...: Same as above but for the writing part of output (and I/O) points.
Data Changes: Number of inputs causing change of value.
The scripting engines are very complex which provides many opportunities for
errors. This can be categorised as follows:
These are seen during runtime as errors in the Error Log, often giving the line
and character of the error. Referring back to the original script should easily
display the problem. Note that if the @VBScript syntax is used within CX-
Supervisor script the line number reported refers just to the lines of VBScript,
with the @VBScript being line 1.
To troubleshoot further:
For specific help on VBScript language syntax see Microsoft's web site at
http://msdn.microsoft.com/scripting
Double check capitalisation, and objects names
See Appendix B FAQ, "What are the syntax differences between VBScript
and CX-Supervisor script?"
To confirm the line causing the problem, temporarily comment it out and
see if the syntax error is no longer reported
As a test, try to simplify complex script lines into 1 or more lines with single
instruction to identify which instruction is causing the error
As a test, simplify complex math formulae into several lines with single
operation to identify which operation is causing the error
As a test, use hardcoded values for parameters using known valid values
Display values using 'MsgBox' command or using the LogEvent command
Confirm path of execution using 'MsgBox' in all conditional branches
These are seen during development when OK is pressed on the Script dialog
box when the script type is 'CX-Supervisor script'.
To troubleshoot further:
Refer to the comprehensive CX-Supervisor Script Reference manual or
on-line help for detailed information including examples on specific script
instructions
Double check capitalisation, and objects names
To confirm the line causing the problem, temporarily comment it out and
see if the syntax error is no longer reported
As a test, try to simplify complex script lines into 1 or more lines with single
instruction to identify which instruction is causing the error
As a test, simplify complex math formulae into several lines with single
operation to identify which operation is causing the error