Electrical connection

General notes
All electrical work should be carried out
by a suitably qualified and competent
person, in strict accordance with na-
tional and local safety regulations.
The voltage and rated load are given
on the data plate. Please ensure that
these match the household mains sup-
ply.
After the appliance has been built in, a
check must be made that all electrical
parts are shielded. No live parts must
be exposed to the touch.
When switched off there must be an all-
pole gap of at least 3 mm in the isolator
switch. For extra safety it is advisable
to install a residual current device
(RCD), with a trip current of 30 mA.
Electrical connection U.K.
The appliance is supplied with a mains
cable for connection to an a.c. single
phase 240 V (230 V), 50 Hz supply.
Connection should be made via a suit-
able isolator which complies with na-
tional and local safety regulations, and
which is accessible after the appliance
has been built in.
Important
The wires in the mains lead are col-
oured in accordance with the following
code:
Green/yellow = earth
Blue
= neutral
Brown
= live
Electrical connection
Electrical connection AUS (NZ)
The appliance is supplied with a mains
cable for connection to an a.c. single
phase or a 2-phase 240 V (230 V),
50 Hz supply. Connection should be
made via a suitable isolator which com-
plies with national and local safety regu-
lations, and which is accessible after
the appliance has been built in.
Test marks
Electrically suppressed according to
AS/NZS 1044
Important
The wires in the mains lead are col-
oured in accordance with the following
code:
Green/yellow = earth
Blue
= neutral
Brown
= live
Black
= live.
In case of a single phase supply
bridge brown and black wires.
WARNING
THIS APPLIANCE MUST BE
EARTHED
In other countries, check with your sup-
plier.
Electrical safety,