Fig. 5. Use oil line adapter bracket to mount
C554A on oil line.
Wiring
Disconnect power supply before beginning wiring to
prevent electrical shock or equipment damage.
All wiring must comply with local electrical codes and
ordinances. See Fig. 6 for a typical C554A hookup to the
oil burner primary control.
THERMOSTAT
(24 VOLT)
C554A
CAD CELL
Fig. 6. Typical hookup for C554A to oil
burner primary control.
OIL LINE ADAPTER
BRACKET
PLUG-IN
SOCKET
CELL
OIL BURNER RELAY
T
T
F
F
M7858
C554A CADMIUM SULFIDE FLAME DETECTOR
CHECKOUT
TO
To check cad cell operation, use the following procedure:
NOZZLE
Disconnect cad cell leadwires; then start burner.
Shortly after burner starts, place a temporary jumper
between terminals F-F. Connect an ohmmeter
across cad cell leadwires; resistance should be less
than 1600 ohms.
Stop burner and remove temporary jumper.
With burner off, check dark cell resistance across
cad cell leadwires. Resistance should be greater
than 20,000 ohms.
M7856
NOTE: If cell resistances are different than
Reconnect cad cell leadwires. Check the
Protectorelay (burner sequencing relay) control
according to the instructions packed with the control.
SERVICE AND REPLACEMENT
Under normal operating conditions, the C554A does not
require cleaning. If a badly adjusted burner causes heavy
accumulation of dirt and soot on the cell surface, carefully
wipe the cell surface to restore full view of the oil flame.
If the C554A is damaged, replace the plug-in portion of the
cell. Order Honeywell part no. 130367 Replacement Cad
Cell.
3
specified, recheck wiring and location of
cell. If necessary, replace plug-in portion of
cell, Honeywell part no. 130367 Replace-
ment Cad Cell.