GROUP ID
00111110
3e
MODEL ID
00001001
09
PARAM TYPE 00000000
00
DATA
0ttttttt
dd0
0aaaaaaa
dd1
0aaaaaaa
dd2
0ddddddd
dd3
:
0ddddddd
ddn
EOX
11110111
F7
Data type:
The "data" field contains the requested number of data bytes from the
requested address, converted from 8-bit to 7-bit form. The MSB's for
seven bytes will be the first byte of data.
Example) [seven bytes of 8 bit data] [8 bytes of 7 bit data]
80 01 82 03 84 05 06
The "data type" is the same as for a Parameter Value Request.
PARAMETER CHANGE (type 0x02:function call)
<Transmission>
If transmission is ON for Control Change ASSIGN or NRPN, this
message is transmitted when an operation causing multiple parameters
to be modified simultaneously is performed. This message is not
received.
STATUS
11110000
F0
ID No.
01000011
43
SUB STATUS 0pppnnnn
1n
GROUP ID
00111110
3e
MODEL ID
00001001
09
PARAM TYPE 00000010
02
DATA
0ttttttt
dd0
0aaaaaaa
dd1
0aaaaaaa
dd2
0ddddddd
dd3
EOX
11110111
F7
function
category/number
--------------------------------------------------------------
0x04 EFF Lib
Recall
LIB No.Bit7-1
(LIB No.1-199, EFF No.0-7)
0x04 EFF Copy
No.Bit7-1
(No.255, EFF No.0-7)
0x05 GEQ Recall
Category Library 126
0x05 GEQ Copy,Link
No.127
0x06 IN EQ Lib Recall
Category Library 126
0x06 IN EQ Copy
Category Copy 127
0x07 OUT EQ Lib Recall Category Library 126
0x07 OUT EQ Copy
Category Copy 127
0x08 IN GATE Lib Recall Category Library 126
0x08 IN GATE Copy
Category Copy 127
0x09 IN COMP Lib Recall Category Library 126
0x09 IN COMP Change
Category Copy 127
0x0a OUT COMP Lib RecallCategory Library 126
0x0a OUT COMP Change
Category Copy 127
0x0b IN CH Lib Recall
Category Library 126
0x0c OUT CH Lib Recall Category Library 126
0x0d IN CH COPY
Source CH No.0-111
0x0e OUT CH COPY
Source CH No.0-73
0x0f IN CH PAIR/LR-MONO *2
0x10 OUT CH PAIR
*2
0x11 SETUP CHANGE
127
(*1 Since multiple destination channels are possible when using
the CH COPY function of the LCD, this will be 127 (fixed)
instead.
*2 0:PAIR L->R, 1:PAIR R->L, 2:RESET BOTH, 3:PAIR RELEASE
4:L-MONO, 5:R-MONO, 6:LR-MONO, 7:L,R,LR-MONO RELEASE )
type
For EFF
BIT5-0:EFFECT TYPE
For GEQ
BIT6:MONO/LINK
For EQ, GATE, COMP, CH, COPY, PAIR
BIT6:MONO/PAIR, BIT5-3:reserved
BIT2:GATE TYPE, BIT1, 0:COMP TYPE
n=0-15(Device Channel
No.1-16)
MODEL ID(digital mixer)
Device code(PM1D)
Current Memory
data type
addressHIGH(BIT13-7)
addressLOW(BIT6-0)
data
End of Exclusive
54 00 01 02 03 04 05 06
System Exclusive Message
Manufacture's ID
No.(YAMAHA)
response for request
n=0-15(Device Channel
No.1-16)
MODEL ID(digital mixer)
Device code(PM1D)
function call
function
category/number
channel/number2
type
End of Exclusive
number2,channel
LIB No..Bit0,
EFF No.0-7
No.Bit0, EFF
No.0-7
GEQ No.0-23
GEQ No.0-23
CH No.0-111
CH No.0-111
CH No.0-73
CH No.0-73
CH No.0-111
CH No.0-111
CH No.0-111
CH No.0-111
CH No.0-73
CH No.0-73
CH No.0-111
CH No.0-73
Destination CH
No.0-111,127 *1
Destination CH
No.0-73,127 *1
CH No.0-111
CH No.0-73
0
For SETUP
0:LOAD,
1:RECALL SAFE INPUT ALL ON,
2:RECALL SAFE INPUT ALL OFF,
3:RECALL SAFE OUTPUT ALL ON,
4:RECALL SAFE OUTPUT ALL OFF
EFF LIBRARY are transmitted when you recall a number that is not
assigned to a program change.
MIDI Data Format
55