3.6.4 Message and Alarm Handling

Alarms
If an alarm occurs, the symbol to the right of the [M3] button becomes visible.
M3
Alarm Icon
Pressing the [M3] button shows the details of the selected alert.
Pressing [M5] leads to alarm acknowledgement and the closure of the window as well as the alarm
icon disappearing. An alarm could occur at every time so the alarm icon can be seen in every view
(in the big views as well as minimized views and ship details list).
Alarms can be set to be displayed <in the foreground > or <minimized >
 Refer to chapter 3.6.5 Configuration of the Graphical Display for details
Safety Related Messages
If a SRM is received, it is displayed immediately.
Pressing [M5] acknowledges the SRM and closes the window. [M6] acknowledges the SRM and
leads you to the text screen for writing an answer.
By pressing [M8] in the "Broadcast Transmission Successful" screen the system returns to the
previous graphical view.