Seagate BARRACUDA 50 Installation Manual page 26

Table of Contents

Advertisement

24
Reserved
Single-Ended Mode option
Use single-ended or low voltage differential mode.
Force the drive to operate only in single-ended mode.
Delay Motor Start option
(valid only if the Enable Motor Start jumper is not connected)
Disable the Delay Motor Start option (default).
Motor start delay equal to the SCSI ID multiplied by 12 seconds.
For example, if the SCSI ID = 2, the drive starts in 24 seconds.
Motor Start option
Disable motor start (default). The drive starts according to the
Delay Motor Start option.
Enable motor start. The drive waits for the Start Unit command
from the host before starting the spindle motor.
Write Protect option
Write protect = Off (enables writing – default).
Write protect = On (disables writing).
Parity Check option
Enable parity check of SCSI bus (default).
Disable parity check.
Figure 7.
Additional jumper options
Barracuda 50 Installation Guide, Rev. A
J6
Drive
Front
J2 Jumper
(enlarged to
show detail)
J2
R
R
S
D
M
W
P
E
E
T
E
S
E
P
D
S
S
P
J2
Pin 1
Pin 2

Advertisement

Table of Contents
loading

This manual is also suitable for:

St150176lwSt150176lc

Table of Contents