Download Print this page

KitchenAid 3397629 Installation Instructions Manual page 6

Advertisement

4. Remove center terminal block screw.
\
5. Remove appliance ground wire (green
with yellow stripes) from external ground
6. Connect ground wire
connector
screw v. Fasten under center,
(green) of power supply cord to
\
._-:-^I
LI--1. ___^...
silver-colored
terrrlrrldl UWCR ww
external
ground conducto' r
screw. Tighten screw.
\
c
n
spade
termin
upturn
external ground
connection
NE,uTRAL
3/d"
U.L.-fi5tS.t
NEUTRAL (white)
strain rellef
\
\
7. c
onnect neutral
wire (white ( or center)
nf
nn\n,or
Cl,,
"I ~v~vc~ --pply
cord
under center screw of
the terminal block.
Tighten screw.
ground
prong
Connect the other wires to outer
block screws. Tighten
ring termGals
Four-wire power supply cord at least four
feet long must have four, No.-1 0 copper
wires and match a four-wire
receptacle of
NEMA Type 14-30R. The fourth wire
(ground conductor)
must be identified
with a green cover and the neutral
conductor
by a white cover.
relief screws.
10.
Insert tab of terminal block cover
into slot of the dryer rear panel. Secure
cover with hold-down
screw.
Preparing the wire:
4. Remove center terminal block screw.
5. Remove appliance ground wire (green
with yellow stripes) from external ground
connector screw. Fasten under center,
6. Connect the qround wire
(bare) of the power supply
cable to the external ground
conductor
screw. Tighten
screw.
silver-colored
terminal block screw.
stripped
of 1
wire'
\
I-
.-p -
8.
Place the hooked ends of the
other power supply cable wires
.
. Place the hooked end
of the neutral wire (white
or center) of power
supply cable under the
center screw of terminal
block (hook facing right).
Squeeze hook end
L---IL--
T!_LL-- --__.
Direct wire cable must have
four feet of extra length so
dryer can be moved if needed.
Strip 5 inches of outer covering
from end of cable. Leave bare
ground wire at 5 inches. Cut
l-l /2 inches from 3 remaining
wires. Strip insulation back
1 inch.
under the outer termtnal block
screws (hook facing right). Squeeze
hooked ends together. Tighten
screws.
rogemer.
I lyriien
SCI
-ew.
llstea stram
relief
to
A:.P.T""srt
\
IO-
*il
au/se, 3-wire
wrt
ground
wire
(Romex)
9. Tighten strain relief screws.
6
Shape
ends
of
wires
into a
hook.
10.
Insert tab of terminal block cover
into slot of dryer rear panel. Secure cover
with hold-down
screw.
1 O-30R Three-wire
receptacle
ductor to neutral wire:
4.
Loosen or remove center terminal
block screw.
5. Connect the neutral wire (white
or center) of power supply cord to
the center, silver-colored
terminal
screw of the terminal block.
Tighten screw.
NEUTRAL
White or cent@
6. Connect the other
wires to outer terminal
block screws. Tighten
screws.
7. Tighten strain relief
screws.
Three-wire
power supply cord at least four
feet long must have three, No.-1 0 copper
wires and match a three-wire
receptacle of
N EMA Type
1 O-30R.
8.
Insert tab of terminal block cover
into slot of dryer rear panel. Secure
cover with hold-down
screw.
Panel D

Advertisement

loading