JVC VN-H37 Manual page 39

Ip camera api guide
Table of Contents

Advertisement

Specify tcpto, IP address, port number, none or object(Number), and the character string to be sent when sending
via TCP. Segments are indicated by /. The number of character string is from 1 to 127 bytes. To use following
characters, specify by hexadecimal number after %.
& / < > # % " { } | \ ^ [ ] `
space
For example, specify 3 characters %20 when inserting a space in the character string. For example, to send the
character string "This is alarm.", specify as "This%20is%20alarm.". %09 and %0D are not available.
Setting Example /api/param?application.event(1).action=tcpto/10.0.0.100/20000/none/Message
To add JPEG, specify object(Number) instead of "none".
Setting Example /api/param?application.event(1).action=tcpto/10.0.0.100/20000/object(1)/Message
Specify udpto, IP address, port number and the character string to be sent when sending via UDP. Segments are
indicated by /. The number of character string is from 1 to 127 bytes. To use following characters, specify by
hexadecimal number after %.
& / < > # % " { } | \ ^ [ ] `
space
For example, specify 3 characters %20 when inserting a space in the character string. For example, to send the
character string "This is alarm.", specify as "This%20is%20alarm.". %09 and %0D are not available.
Setting Example /api/param?application.event(1).action=udpto/10.0.0.100/20000/Message
Specify scene file number when switch scene file is specified.
Setting Example /api/param?application.event(1).action=camera.image.scene(7).status/goto
Specify preset position number when preset position is specified.
Setting Example /api/param?application.event(1).action=camera.position(2).status/goto
[VN-H57/157WP/257/257VP Only] Specify audio file number when audio file playback is specified. The audio file
number can be from 01 to 05.
Setting Example /api/param?application.event(1).action=audioplay/audiofile02/ch01
[VN-H57/157WP/257/257VP Only] Specify pinout, distinction between make/break (m1 or b1) and the time
(millisecond) when alarm output is specified. Segments are indicated by /. The time is 0 or from 100 to 5000.
When the time is 0, alarm output does not come back to previous state.
Setting Example /api/param?application.event(1).action=pinout/m1/1500
Alarm action of event number 6 is periodic FTP. Other Event number can not be set to periodic FTP. Parameters
of FTP can be set by another API, application.ftp.
Setting Example /api/param?application.event(6).action=ftpto/ftp01/object(6)