Setting Full Mask - Pioneer PDP-502MX Manual

Plasma display monitor
Hide thumbs Also See for PDP-502MX:
Table of Contents

Advertisement

Integrator Mode

10) Setting FULL MASK

This is a function for turning the whole screen a single color - white, red, green or blue - using a PDP internal signal.
If FULL MASK is set to any setting other than OFF then display of external input signals becomes impossible.
The FULL MASK feature may be used to wipe out to some extent images which have been burnt into the screen.
(Note, however, that it is impossible to completely eliminate such images.)
For more details please refer to "5.8 Regarding the problem of images becoming burnt onto the screen".
Factory preset :
1 Enter the integrator mode (refer to section 5.4.1, "About
the integrator mode").
The ID number of the unit of adjustment items will be indicated
in the upper right corner of the screen, where "– –"is displayed
in the illustration.
Select OPTION 2.
2 Move the cursor to "FULL MASK" and change the mode
with the SET button.
You can cycle through the available values by repeatedly
pressing the SET button:
OFF = ON = RED = GREEN = BLUE = ···
FULL MASK applies to all inputs (INPUTs 1 to 4).
Select EXIT in screen 2 to return to screen 1.
120
OFF
Screen 1
MENU
PICTURE
WHITE BAL.
SCREEN
]
SIDE MASK
OPTION 1
3OPTION 2
SUB VOLUME
ALL DEFAULT
Screen 2
OPTION 2
OSD
BAUD RATE
FULL MASK
]
3FAN CONTROL : AUTO
TEMPERATURE :
HOUR METER
EXIT
– –
– –
: ON
:
4 8 0 0 BPS
: OFF
:
3 4 5 HRS