Hide thumbs Also See for PALOMA-BZ-MOD:
Table of Contents

Advertisement

Quick Links

Model(s):
PALOMA-BZ-MOD
PALOMA-GR-MOD
PALOMA-GY-MOD
• Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING: If the information in these
instructions is not followed exactly, a fi re
or explosion may result causing property
damage, personal injury, or death.
• Do not store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of
this or any other appliance.
• What to do if you smell gas
- Do not try to light any appliance.
- Do not touch any electrical switch. Do not
use any phone in your building.
- Immediately call your gas supplier from
a neighbor's phone. Follow the gas sup-
plier's instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or the
gas supplier.
This appliance may be installed as an OEM installation in
manufactured home (USA only) or mobile home and must be
installed in accordance with the manufacturer's instructions
and the manufactured home construction and safety standard,
Title 24 CFR, Part 3280 or Standard for Installation in Mobile
Homes, CAN/CSA Z240MH.
This appliance is only for use with the type(s) of gas indicated
on the rating plate.
Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12
CAUTION
DO NOT DISCARD THIS MANUAL
• Read, understand and follow
these instructions for safe
installation and operation.
Owner's Manual
Installation and Operation
• Leave this manual with
party responsible for use
and operation.
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• Do not touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
fi replace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other fl ammable
materials.
• Keep clothing, furniture, draperies and other fl ammable
materials away.
In the Commonwealth of Massachusetts:
• installation must be performed by a licensed plumber
or gas fi tter;
See Table of Contents for location of additional
Commonwealth of Massachusetts requirements.
Installation and service of this appliance should be
performed by qualifi ed personnel. Hearth & Home
Technologies suggests NFI certifi ed or factory trained
professionals, or technicians supervised by an NFI
certifi ed professional.
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo PALOMA-BZ-MOD

  • Page 1 Title 24 CFR, Part 3280 or Standard for Installation in Mobile Homes, CAN/CSA Z240MH. This appliance is only for use with the type(s) of gas indicated on the rating plate. Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 2 00,000 00,000 00,000 MIN. MIN. INPUT INPUT BTUH: BTUH: 00,000 00,000 00,000 00,000 Serial Serial ORIFICE ORIFICE SIZE: SIZE: #XXXXX #XXXXX #XXXXX #XXXXX XXXXXXXX XXXXXXXX (Serie): (Serie): Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 3: Table Of Contents

    D. Loss of Power and Battery Backup Usage ... . 29 E. Wall Switch Installation for Fan (Optional) ... . 30  = Contains updated information. Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 4: Listing And Code Approvals

    BTU/h (DMS) Effi ciency % locations such as in bathrooms or near sinks. Paloma (NG) 28,000 20,000 Paloma (LP) 26,000 19,000 *Maximum Vent Blower On **Canada Only Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 5: Requirements For The Commonwealth Of Massachusetts

    VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB- of the installation. STRUCTIONS”. See Gas Connection section for additional Common- wealth of Massachusetts requirements. Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 6: Getting Started

    1/2 - 3/4 inch length, #6 or #8 Self-drilling screws One 1/4 inch female connection (for optional fan) Caulk with a minimum of 300ºF continuous exposure rating Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 7: Framing And Clearances

    (see fi gure 3.1). “A” MEASUREMENT IS FROM APPLIANCE TOP, NOT SIDE ALCOVE Model Inches 10-1/8 12-1/8 30-3/4 13-1/4 13-1/4 15-1/2 Paloma Millimeters 1372 Figure 3.1 Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 8: Clearances To Combustibles

    fl oor strong enough to support gas stove without tipping. • USE wood fl ooring, ceramic tile, brick hearth or high pressure laminate fl ooring applied directly over the sub-fl ooring material. Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 9: Termination Locations

    In a staggered installation with both gas and wood or fuel oil terminations, the wood or fuel oil termination cap must be higher than the gas termination cap. Figure 4.3 Staggered Termination Caps Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 10 Figure 4.4 Minimum Clearances for Termination CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS SUGGESTED THAT A VINYL PROTECTOR KIT BE INSTALLED. Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 11: Vent Information

    Figure 4.1) on page 9. 3. Vertical terminations are measured to the top of the last pipe before termination cap. 4. Horizontal pipe installed level with 1/4 inch rise per foot. Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 12: How To Use The Vent Graph

    1/4 in. (6 mm) rise per foot. For rear vent or top of appliance for top 6 in. (152 mm) Minimum starter pipe vent. Figure 5.2 Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 13: Horizontal Termination

    • Pipe may separate if not properly joined. material, i.e. masonry block or concrete, a 7 in. (178 mm) diameter hole is acceptable. Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 14 The vent terminal cap shall not be recessed into a wall or siding. Remove siding from the area where the standoff will be located. Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 15 Note: The attachment from the vent pipe to the vent termination cap must be sealed with silicone. Termination caps shall not be recessed into a wall or siding. Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 16: Vertical Termination

    • Do not pack air space with insulation or other materials. Failure to keep insulation or other materials Figure 5.12 away from vent pipe may cause fi re. Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 17 Figure 5.14. Verify that the chimney is the required height above the roof. See roof pitch table, Figure 4.2, on page 9. Figure 5.15 Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 18: Secure The Vent Sections

    Figure 10.9 Securing Horizontal Pipe Sections pipe and the combustible surfaces of the enclosure. Do not fill any of the required air space with insulation. Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 19: Disassemble Vent Sections

    Ensure that all pipe and elbow connections are in their fully twist-locked position. Assemble as instructed. Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 20: Class A Metal Chimney

    (Figure 5.21). TOP ADAPTER CATHEDRAL CEILING SUPPORT BOX SCREWS Figure 5.19 FLEX PIPE SHEET METAL SCREWS Figure 5.21 Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 21: Existing Masonry Chimney

    This allows the retro connector to mount vent pipe. directly on the masonry and provide the correct clearances to combustibles (Figure 5.25). Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 22 (Figure 5.28). Twist lock the Figure 5.26 high wind termination cap on to the top adapter. Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 23 6 in. (152 mm) DIAMETER OPENING IN MASONRY WALL RETRO CONNECTOR THREE MASONRY BOLTS (NOT INCLUDED) Figure 5.29 Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 24: Slim Line Wall Thimble

    254 mm). sharp. The four trim ring mounting screws provided should be replaced with appropriate fasteners for stucco, brick, con- crete, or other types of sidings. Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 25 REAR OF STOVE WALL THIMBLE CENTER LINE HTI VENT HHW2 PART #841-0670 (RECOMMENDED HEAT SHIELD OVER FOR OPTIMUM PERFORMANCE) TOP HALF OF PIPE TRIM RING Figure 5.35 Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 26: Gas Information

    Contact the local gas supplier if the regulator is at an improper pressure. Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 27: Gas Connection

    • Purge should be performed by qualifi ed technician. • Ensure adequate ventilation. • Ensure there are no ignition sources such as sparks or open fl ames. Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 28: Electrical Information

    20 gauge 25 feet unplugged if the battery pack is used. 22 gauge 18 feet Figure 7.1 NOTICE: Battery polarity must be correct or module damage will occur. Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 29: Loss Of Power And Battery Backup Usage

    • Do not install batteries if the backup mode may not be used for extended time. • Batteries may leak. • Install batteries only when needed for power outage. BATTERY LOCATION Figure 7.3 Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 30: Wall Switch Installation For Fan (Optional)

    SWITCH MINIMUM 14-3 AWG WITH GROUND Black Black White White Green Green JUNCTION BOX POWER SUPPLY WIRES SWITCH BOX Figure 7.4 Junction Box Wired to Wall Switch Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 31: Appliance Setup

    Using the black grommet located in the component bag, slide it into the bottom of the back panel and feed the power cord through the grommet, as shown in Figure 8.1. Figure 8.2 Figure 8.1 Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 32: Leveling And Lagging Down The Appliance

    • Using non-listed accessories voids warranty. ance. • Using non-listed accessories may result in a safety hazard. • Only Hearth & Home Technologies approved accessories may be used safely. Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 33: Top To Rear Vent Conversion

    4. Remove the four screws from the DV adapter collar. (Figure 8.9) Set aside DV adapter collar, gasket and screws. 5. Remove the inner extension starter collar (Shown in Figure 8.9) and set aside. Figure 8.11 Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 34: Shutter Adjustment

    For vertical venting above 15 ft. a vent restrictor is required. Figure 8.13 Air Shutter Settings PALOMA-BZ-MOD PALOMA-GR-MOD PALOMA-GY MOD Rear Vent 1/2 in. 1/2 in. Top Vent 3/8 in. 1/2 in. Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 35: Installing Rock Media And Ember Material

    • Do NOT use any media other than the rock clusters supplied with this fi replace. Fireplace will not function properly. Delayed ignition may occur. Figure 3. Placing Right Rock Cluster Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 36 Failure to follow this procedure will likely cause lighting and sooting problems. LEFT ROCK CLUSTER EMBERS BASEPAN LEDGE Figure 5. Placing Left Rock Cluster Figure 7. Ember Placement Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 37: Optional Blower

    Electric Code ANSI/NFPA NO. 70-current (in the United wires into the slots indicated in Figure 8.28. States), or with the current CSA C22.1 Canadian Electric Code (in Canada). Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 38 "ON" position. FAN BASE CONTACTS FAN BASE CONTACTS FAN BRACKET FAN BRACKET Figure 8.25 Figure 8.27 Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 39 The blower can be turned off manually with the speed control switch. Figure 8.28 Blower Wiring Diagram WARNING! Risk of Shock! Replace damaged wire with type 105º C rated wire. Wire must have high temperature insulation. Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 40: Remote Controls

    SCREW 3 Prong Cord 3 Prong Cord VARIABLE REGULATOR WASHER Wires Ties Wires Ties FLAME CONTROL SOLENOID JAM NUT PLUNGER Figure 8.29 Figure 8.30 Flame Control Solenoid Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 41 GROUND TO FIREPLACE CHASSIS PLUG RED JUMPER WIRE TO BROWN VALVE BATTERY PACK PIGGYBACK ON/OFF SWITCH FLAME CONTROL SOLENOID ORANGE ORANGE Figure 8.31 Remote Control IPI Wiring Diagram Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 42: Front Door Glass Assembly Replacement

    Screw • Replace glass door as a complete assembly. Finishing Cap Protective barrel sleeve through hole in the glass Figure 8.33 Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 43: Operating Instructions

    Refer to the owner’s information manual provided with this appliance. For assistance or additional information consult a qualifi ed Figure 9.1 installer, service agency or the gas supplier. Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 44: Lighting Instructions (Ipi)

    See installation and operating instructions accompanying appliance. For additional information on operating your Hearth & Home Technologies fi replace, please refer to www.fi replaces.com. Final inspection by Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 45: After Appliance Is Lit

    Some optional control systems available with IPI models may allow pilot fl ame to continually? remain lit. In a standing pilot system the pilot will always stay on. Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 46: A. Intellifire Ignition System

    Verify module is securely grounded to metal chassis of appliance. D. Module voltage output / Valve/Pilot Verify battery voltage is at least 2.7 volts. Replace batteries if volt- solenoid ohms readings. age is below 2.7. Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 47 ON position. If there is no spark at “I” terminal module must be replaced. If there is a spark at “I” terminal, module is fi ne. Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 48: Maintaining And Servicing Appliance

    • Restricted air fl ow affects burner operation. • Air passageways, grilles, control compartment • Burner, burner ports Risk of: • Fire • Delayed ignition or explosion • Exposure to combustion fumes • Odors Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 49: Maintenance Tasks

    4. Inspect for corrosion or separation. 5. Verify weather stripping, sealing and fl ashing remains intact. Remote controls 1. Verify operation of remote. 2. Replace batteries in remote transmitters and battery-powered receivers. Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 50: Reference Materials

    Height includes 3/8 in (9.53 mm) hearth pad Location Inches Millimeter Location Inches Millimeter 18-7/8 7-1/8 40-3/4 1035 40-3/8 1025 28-7/8 15-7/8 34-5/8 Figure 12.1 Appliance Dimensions Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 51: Vent Components Diagram

    167 mm 167 mm 167 mm 167 mm SLP48 SLP12 SLP36 SLP24 Note: Pipes overlap 1-3/8 inches (34.93 mm) at each joint. Figure 12.3 SLP Series Vent Components Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 52: Vent Components List

    Retrofit Adj. Chimney Connector Retrofit Chimney Connector Plate HTI-DV-WT Wall Thimble SLP-SA Flue Adaptor NOTICE: The PVK-80 power vent kit is NOT approved for use with PALOMA-BZ-MOD, PALOMA-GR-MOD, or PALOMA-GY-MOD. Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 53: Service Parts

    Service Parts Diagram Beginning Manufacturing Date: Aug 2009 Ending Manufacturing Date: ______ Paloma-GY-MOD ( Gray), Paloma-GR-MOD ( Green), Paloma-BZ-MOD (Bronze)) Rock Placement Part number list on following page. Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 54 Side Assembly Right 2123-026 Back Panel Assembly Vertical 7031-021 Back Panel Assembly Horizontal 7031-022 Cover Plate 2189-111 Cover Plate Gasket 7010-160 Additional service part numbers appear on following page. Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 55 Male connector Pkg of 5 303-315/5 22.8 Flex Ball Valve Assembly 2098-034 22.9 Flex 12" 383-302A 22.10 Pilot Bracket 2189-119 Additional service part numbers appear on following page. Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 56 Rear Vent Conversion Kit VRT-TR-AU Bronze PAL-GLS-BZ Front Glass Green PAL-GLS-GR Smoke PAL-GLS-GY Bronze HP-PAL-BZ Standard Hearth Pad Green HP-PAL-GR Smoke HP-PAL-GY Touch Up Paint (Pewter) TUPNP-12 Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 57: Limited Lifetime Warranty

    Firebox and heat exchanger Lifetime All replacement parts 90 Days beyond warranty period See conditions, exclusions, and limitations on next page. 4021-645C 12-29-10 Page 1 of 2 Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 58 E. Limited Lifetime Warranty (continued) WARRANTY CONDITIONS: WARRANTY EXCLUSIONS: This warranty is void if: LIMITATIONS OF LIABILITY: 4021-645C 12-29-10 Page 2 of 2 Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...
  • Page 59: Contact Information

    5647340, 5890485, 5941237, 5947112, 5996575, 6006743, 6019099, 6053165, 6145502, 6170481, 6374822, 6484712, 6601579, 6769426, 6863064, 7077122, 7098269, 7258116, 7470729 or other U.S. and foreign patents pending. 2000-945 Printed in U.S.A. - Copyright 2012 Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 Rev. i • 5/12...

This manual is also suitable for:

Paloma-gr-modPaloma-gy-mod

Table of Contents