Rear Vent Configuration With Horizontal Termination (No Vertical Rise) - Travis Industries 864 HH Installation Manual

Built-in direct vent fireplace
Hide thumbs Also See for 864 HH:
Table of Contents

Advertisement

Rear Vent Configuration with Horizontal Termination (no vertical rise)

Vent with No 45° Elbow
3 feet
0 feet
Vent with 1 45° Elbow
3 feet
0 feet
See the charts above to
determine maximum vent
Optional 45° Elbow
EXHAUST RESTRICTOR REMOVAL
Termination
• Exhaust Restrictor Removed
• Intake Restrictor # 1 (stock)
• Diffuser Position # 1 (stock)
• Min. 4" Horizontal Section
• Max.48" Horizontal Section(s)
• Exhaust Restrictor Removed
• Intake Restrictor # 1 (stock)
• Diffuser Position # 1 (stock)
• Min. 4" Horizontal Section
• Max. 24" Horizontal Section(s)
If venting to the rear with no vertical
sections, remove and discard the exhaust
restrictor. Replace the screws in the same
holes.