SJ700
When installed for use with an SJ700 inverter, the 115VIF-DIN must be mounted within the panel and in close
proximity to the inverter. Please connect wiring leads (20 AWG) pigtail leads from the 115VIF-DIN to the I/O
terminal strip of the SJ700 inverter. Connect the leads one by one to intelligent input terminals on the inverter
following the same numeration coding as labeled and similarly shown on the 115VIF-DIN interface label, see
Figure 2-3 on page 7. Also the FW must be used to activate the EzSQ program.
Open-Loop vs. Closed-Loop SJ700
For open-loop applications: the UP (blue) wire from the pigtail is connected to the FW terminal. In this case
there is no connection to intelligent input 1, which is configured for no function [NO].
For closed-loop (encoder feedback) applications: the UP (blue) wire from the pigtail is connected to
intelligent input terminal 1, which is configured for [MI1] function. Refer to parameter tables in Chapter 3.
Sinking/Sourcing Input Set-up
On the SJ700, the factory default setting for the intelligent inputs is for sinking logic. The 115VIF-DIN interface
requires the inputs be set for sourcing logic for proper operation. To change the logic setting, locate the small
metal jumper bar on the intelligent input terminal strip. Then:
1) Remove the jumper from its default position (shown below) between the P24 terminal and PLC
terminal.
2) Reinstall the jumper between the PLC terminal and the CM1 terminal
(1) M3 x 8 mm