Shutting The Projector Down; Resetting All Settings - Hitachi CP-X200 User Manual

Hide thumbs Also See for CP-X200:
Table of Contents

Advertisement

Regarding the indicator lamps (continued)
POWER
LAMP
indicator
indicator
Blinking
In
Red
Turned
or
off
Lighting
In
Red
Lighting
Simultaneous
In
Green
blinking in
Lighting
Alternative
In
Green
blinking in
NOTE • When the interior portion has become overheated, for safety purposes,
the projector is automatically shut down, and the indicator lamps may also be
turned off. In such a case, disconnect the power cord, and wait at least 45 minutes.
After the projector has sufficiently cooled down, please make confirmation of the
attachment state of the lamp and lamp cover, and then turn the power on again.

Shutting the projector down

Only when the projector can not be turned off by usual
procedure (15), please push the shutdown switch
using a pin or similar, and disconnect the power plug
from the power outlet. Before turning it on again, wait
at least 10 minutes to make the projector cool down
enough.

Resetting all settings

When it is hard to correct some wrong settings, the FACTORY RESET function of
SERVICE item in OPTION menu
FILTER TIME, LAMP TIME, FILTER MESSAGE and etc.) to the factory default.
TEMP
indicator
There is a possibility that the interior portion
has become heated.
Please turn the power off, and allow the projector to cool down at least
20 minutes. After the projector has sufficiently cooled down, please make
confirmation of the following items, and then turn the power on again.
Lighting
• Is there blockage of the air passage aperture?
In
Red
• Is the air filter dirty?
• Does the peripheral temperature exceed 35°C?
If the same indication is displayed after the remedy, please
set FAN SPEED of SERVICE item in OPTION menu to HIGH
(42)
.
It is time to clean the air filter.
Please immediately turn the power off, and clean or change
the air filter referring to the section "Air Filter". After cleaning or
Red
changing the air filter, please be sure to reset the filter timer.
After the remedy, reset the power to ON.
There is a possibility that the interior portion
has become overcooled.
Please use the unit within the usage temperature
Red
parameters (5°C to 35°C).
After the treatment, reset the power to ON.
(44)
Description
can reset all settings(except LANGUAGE,
Troubleshooting
Shutdown switch
57

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cp-x300Cp-x400

Table of Contents