Symptom
Loss of Suction
Motor Won't Run
WARNING
Always disconnect power cable from electrical outlet when
working on this vacuum cleaner.

TROUBLESHOOTING GUIDE

Possible Cause
1. Obstruction in hose or wand
2. Clogged air filter assembly
3. Uneven gasket fit
4. Dented collection can rim
1. Defective switch.
2. Defective power cord
3. Defective motor brush
10702 N 46th Street • Tampa,FL 33617
(813)971-2223 • fax (813) 971-6090
www.pullmanholtcorp.com
Corrective Action
1. Reverse hose on tank inlet.
2. Tap Never-Clog
Bag or wash if necessar y. Replace HEPPA filter.
®
3. Reposition or replace gasket.
4. Replace can.
1. Replace switch.
2. Replace power cord.
3. Replace motor brush.