Electrical Requirements - Whirlpool ACE082PT1 Use & Care Manual

Table of Contents

Advertisement

Available languages

Available languages

Window
Installation
Window opening measurements:
27" min. to 38" max. (68.6 cm to 95.5 cm) opening width.
161/4 '' min. (41.3 cm) opening height.
E
!
t
B
J
A. 27" min. (68.6 cm)
B. 16_" min. (41.3 cm)
Through-the-Wall
Installation
The wall opening measurements
should be:
Height: 16" (40.6 cm) plus twice the thickness of wood used
to build frame.
Width: 22%" (57.5 cm) plus twice the thickness of wood used
to build frame.
Depth: Dimension for depth depends on wall thickness and
type of molding.
B c
t
C
A. 16" (40.6 cm)
C. Wood thickness
B. 22_"
(57.5 cm)
D. Depth
Electrical Shock Hazard
Plug into a grounded
3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Ground wire must be connected to the ground screw located in
the lower right corner of the air conditioner when the air
conditioner
is in the cabinet.
Power Supply Cord
Wiring Requirements
230-volt (207 min. to 253 max.)
(0.6 cm)
0 to 12 amps
15-amp time-delay fuse or
circuit breaker
Use on single outlet circuit only.
230-volt (207 min. to 253 max.)
0 to 16 amps
20-amp time-delay fuse or
circuit breaker
Use on single outlet circuit only.
The electrical ratings for your air conditioner
are listed on the
model and serial number label. The model and serial number
label is located behind the front panel on the flange below the
control panel area.
Specific electrical requirements are listed in the chart below.
Follow the requirements for the type of plug on the power supply
cord.
Power Supply Cord
Wiring Requirements
115-volt (103.5 min. to 126.5 max.)
0 to 12 amps
15-amp time-delay fuse or
circuit breaker
Use on single outlet circuit only.
230-volt (207 min. to 253 max.)
1/2"
(1.3cm)
0to24amps
_
_
30-amp time-delay fuse or
circuit breaker
Use on single outlet circuit only.
Recommended Grounding Method
This air conditioner
must be grounded. This air conditioner
is
equipped with a power supply cord having a grounded 3 prong
plug. To minimize possible shock hazard, the cord must be
plugged into a mating, grounded 3 prong outlet, grounded in
accordance with all local codes and ordinances. If a mating outlet
is not available, it is the customer's
responsibility
to have a
properly grounded 3 prong outlet installed by a qualified electrical
installer.