Base Grille Water Filtration
System
(_
Tested and certified
by NSF International
against
ANSI/NSF
Standard
42 for the reduction
of Chlorine Taste and Odor, Particulate
Class II*; and against
ANSI/NSF
Standard
53 for the reduction
of Lead,
Mercury,
Benzene,
Toxaphene,
p-dichlorobenzene,
and Carbofuran.
This system
has been tested according
to ANSl/NSF
42/53 for the reduction
of the substances
listed below. The concentration
of the
indicated
substances
in water entering
the system
was reduced
to a concentration
less than or equal to the permissible
limit for water
leaving the system, as specified
in ANSl/NSF
42/53.
Model WF-NL240V/NL240V
Capacity
240 Gallons
Substance
Reduction
Aesthetic
Effects
Chlorine Taste/Odor
Particulate Class II*
Contaminant
Reduction
Lead: @ pH 6.5
Lead: @ pH 8.5
Mercury: @ pH 6.5
Mercury: @ pH 8.5
Benzene
3-dichlorobenzene
Toxaphene
Carbofuran
(908 Liters)
NSF Reduction
Requirements
>-50%
>_85%
NSF Reduction
Requirements
0.01 mg/L
0.01 mg/L
0.002 mg/L
0.002 mg/L
0.005 mg/L
0.075 mg/L
0.003 mg/L
0.04 mg/L
Average
Influent
1.94 mg/L
833,333/mL
Average
Influent
0.15 mg/L***
0.148 mg/L***
0.006 mg/L
0.0061 mg/L
0.014 mg/L
0.235 mg/L
0.014 mg/L
0.077 mg/L
Influent Challenge
Concentration
2.0 mg/L_+ 10%
At least 10,000
particles/ml
Influent Challenge
Concentration
0.15 rag/L_+ 10%
0.15 mg/L_+ 10%
0.006 mg/L _+10%
0.006 mg/L _+10%
0.015 _+10%
0.225 _+10%
0.015 _+10%
0.080 _+10%
Maximum
Effluent
0.05 mg/L
100,000/mL**
Maximum
Effluent
O.0Ol mg/L
0.003 mg/L
0.0002 mg/L
0.0009 mg/L
0.0005 mg/L
0.0019 mg/L
0.0012 mg/L
0.031 mg/L
Average
Effluent
0.05 mg/L
40,667/mL
Average
Effluent
0.001 mg/L
0.001 mg/L
0.0002 mg/L
0.00052 mg/L
0.0005 mg/L
0.0009 mg/L
0.001 mg/L
0.0064 mg/L
Minimum %
Reduction
97.4%
88.0%
Minimum %
Reduction
99.3%
97.9%
96.60%
85.2%
96.06%
99.1%
92.7%
61.03%
Average %
Reduction
97.4%
95.1%
Average %
Reduction
99.3%
99.0%
96.6%
91.8%
96.06%
99.6%
92.6%
91.94%
Model WF-L400V/L400V
Capacity
400 Gallons (1514 Liters)
Substance
Reduction
NSF Reduction
Average
Influent Challenge
Maximum
Average
Minimum %
Average %
Aesthetic
Effects
Requirement
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Chlorine Taste/Odor
_>50%
1.94 mg/L
2.0 mg/L _+10%
0.05 mg/L
0.05 mg/L
97.4%
97.4%
Particulate Class II*
>_85%
833,333/mL
Atparticles/mlleast
10,000
100,000/mL**
40,667/mL
88.0%
95.1%
Contaminant
NSF Reduction
Average
Influent Challenge
Maximum
Average
Minimum %
Average %
Reduction
Requirement
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Lead: @ pH 6.5
0.01 mg/L
0.15 mg/L***
0.15 mg/L _+10%
0.001 mg/L
0.001 mg/L
99.3%
99.3%
Lead: @ pH 8.5
0.01 mg/L
0.148 mg/L***
0.15 mg/L _+10%
0.003 mg/L
0.0014 mg/L
97.9%
99.3%
Mercury: @ pH 6.5
0.002 mg/L
0.0061 mg/L
0.006 mg/L _+10%
0.0002 mg/L
0.0002 mg/L
96.60%
96.6%
Mercury: @ pH 8.5
0.002 mg/L
0.0061 mg/L
0.006 mg/L _+10%
0.0009 mg/L
0.00052 mg/L
85.2%
91.8%
Benzene
0.005 mg/L
0.014 mg/L
0.015 _+10%
0.0005 mg/L
0.0005 mg/L
96.06%
96.06%
p-dichlorobenzene
0.075 mg/L
0.235 mg/L
0.225 _+10%
0.0019 mg/L
0.0009 mg/L
99.1%
99.6%
Toxaphene
0.003 mg/L
0.014 mg/L
0.015 _+10%
0.0012 mg/L
0.001 mg/L
92.7%
92.6%
Carbofuran
0.04 mg/L
0.077 mg/L
0.080 _+10%
0.031 mg/L
0.0064 mg/L
61.03%
91.94%
It is essential
that operational,
maintenance,
and filter
replacement
requirements
be carried out for the product
to
perform
as advertised.
Model WF-NL2ZK)V: Change
cartridge
at least every 6 months.
Use replacement
cartridge
NL240V, part #4396509.
2006
suggested
retail price of $35.99 U.S.A./S59.95
Canada.
Prices
are subject
to change without
notice.
Model WF-L400V:
The filter monitor
system
measures the
amount
of water that passes through the filter and alerts you to
replace the filter. When 90% of the filter's rated life is used, the
filter indicator
light changes
from green to yellow. When 100% of
the filter's rated life is used, the filter indicator
light changes
from
yellow to red, and it is recommended
that you replace the filter.
Use replacement
cartridge
L400V, part #4396509.
2006
suggested
retail price of $35.99 U.S.A./S59.95
Canada.
Prices are
subject to change without
notice.
•
The product
is for cold water use only.
•
Do not use with water that is microbiologically
unsafe or of
unknown
quality without
adequate
disinfection
before or after the
system.
•
Refer to the front cover or "Assistance
or Service"
section for the
Manufacturer's
name, address and telephone
number.
•
Refer to the "Warranty"
section for the Manufacturer's
limited
warranty.
Application
Guidelines/Water
Supply
Parameters
Water Supply
City or Well
Water Pressure
30 - 120 psi (207 - 827 kPa)
Water Temperature
33 ° - 100°F (0.6 ° - 37.8°C)
Service
Flow Rate
0.5 gpm (1.9 L/min.) @ 60 psi.
*Class II particle size: >1 to <5
**Test requirement is at least 100,000 particles/mL
of AC Fine Test Dust.
***These contaminants
are not necessarily in your water supply. Performance
may vary based on local water conditions.
(¢ NSF is a registered trademark
of NSF International.
13